MétaCan
Menu
Back to cohort
Record W2981290158

Intraocular lenses for the treatment of age-related cataracts: an evidence-based analysis.

2009· article· en· W2981290158 on OpenAlexaboutno aff

Bibliographic record

VenuePubMed · 2009
Typearticle
Languageen
FieldMedicine
TopicOphthalmology and Visual Impairment Studies
Canadian institutionsnot available
Fundersnot available
KeywordsCataractsMedicineIntraocular lensesOphthalmologyOptometryCataract surgeryIntraocular lensPopulation
DOInot available

Abstract

fetched live from OpenAlex

OBJECTIVE: The objective of the report is to examine the comparative effectiveness and cost-effectiveness of various intraocular lenses (IOLs) for the treatment of age-related cataracts. CLINICAL NEED: TARGET POPULATION AND CONDITION A cataract is a hardening and clouding of the normally transparent crystalline lens that may result in a progressive loss of vision depending on its size, location and density. The condition is typically bilateral, seriously compromises visual acuity and contrast sensitivity and increases glare. Cataracts can also affect people at any age, however, they usually occur as a part of the natural aging process. The occurrence of cataracts increases with age from about 12% at age 50 years, to 60% at age 70. In general, approximately 50% of people 65 year of age or older have cataracts. Mild cataracts can be treated with a change in prescription glasses, while more serious symptoms are treated by surgical removal of the cataract and implantation of an IOL. In Ontario, the estimated prevalence of cataracts increased from 697,000 in 1992 to 947,000 in 2004 (35.9% increase, 2.4% annual increase). The number of cataract surgeries per 1,000 individuals at risk of cataract increased from 64.6 in 1992 to 140.4 in 1997 (61.9% increase, 10.1% annual increase) and continued to steadily increase to 115.7 in 2004 (10.7% increase, 5.2% increase per year). DESCRIPTION OF TECHNOLOGY/THERAPY: IOLs are classified either as monofocal, multifocal, or accommodative. Traditionally, monofocal (i.e.. fixed focusing power) IOLs are available as replacement lenses but their implantation can cause a loss of the eye's accommodative capability (which allows variable focusing). Patients thus usually require eyeglasses after surgery for reading and near vision tasks. Multifocal IOLs aim to improve near and distant vision and obviate the need for glasses. Potential disadvantages include reduced contrast sensitivity, halos around lights and glare. Accommodating IOLs are designed to move with ciliary body contraction during accommodation and, therefore, offer a continuous range of vision (i.e. near, intermediate and distant vision) without the need for glasses. Purported advantages over multifocal IOLs include the avoidance of haloes and no reduction in contrast sensitivity. Polymethyl methacrylate (PMMA) was the first material used in the fabrication of IOLs and has inherent ultraviolet blocking abilities. PMMA IOLs are inflexible, however, and require a larger incision for implantation compared with newer foldable silicone (hydrophobic) and acrylic (hydrophobic or hydrophilic) lenses. IOLs can be further sub-classified as being either aspheric or spheric, blue/violet filtered or non-filtered or 1- or 3-piece. METHODS OF EVIDENCE-BASED ANALYSIS: A literature search was conducted from January 2003 to January 2009 that included OVID MEDLINE, MEDLINE In-Process and Other Non-Indexed Citations, EMBASE, the Cumulative Index to Nursing & Allied Health Literature (CINAHL), The Cochrane Library, and the International Agency for Health Technology Assessment/Centre for Review and Dissemination. Inclusion CriteriaExclusion Criteriaadult patients with age-related cataractssystematic reviews, randomized controlled trials (RCTs) PRIMARY OUTCOMES: distance visual acuity (best corrected distance visual acuity), near visual acuity (best distance corrected near visual acuity) SECONDARY OUTCOMES: contrast sensitivity, depth of field, glare, quality of life, visual function, spectacle dependence, posterior capsule opacification.studies with fewer than 20 eyesIOLs for non-age related cataractsIOLs for presbyopiastudies with a mean follow-up <6monthsstudies reporting insufficient data for analysis COMPARISONS OF INTEREST: The primary comparison of interest was accommodative vs. multifocal vs. monofocal lenses. Secondary comparisons of interest included: tinted vs. non-tinted lensesaspheric vs. spheric lensesmultipiece vs. single piece lensesbiomaterial A (e.g. acrylic) vs. biomaterial B (e.g. silicone) lensessharp vs. round edged lensesThe quality of the studies was examined according to the GRADE Working Group criteria for grading quality of evidence for interventional procedures. SUMMARY OF FINDINGS: The conclusions of the systematic review of IOLs for age-related cataracts are summarized in Executive Summary Table 1. CONSIDERATIONS FOR THE ONTARIO HEALTH SYSTEM: Procedures for crystalline lens removal and IOL insertion are insured and listed in the Ontario Schedule of Benefits.If a particular lens is determined to be medically necessary for a patient, the cost of the lens is covered by the hospital budget. If the patient chooses a lens that has enhanced features, then the hospital may choose to charge an additional amount above the cost of the usual lens offered.An IOL manufacturer stated that monofocal lenses comprise approximately 95% of IOL sales in Ontario and premium lenses (e.g., multifocal/accomodative) consist of about 5% of IOL sales.A medical consultant stated that all types of lenses are currently being used in Ontario (e.g., multifocal, monofocal, accommodative, tinted, nontinted, spheric, and aspheric). Nonfoldable lenses, rarely used in routine cases, are primarily used for complicated cataract implantation situations.ES Table 1:Conclusions for the Systematic Review of IOLs for Age-Related CataractsComparisonConclusionGRADE QualityMultifocal vs. monofocalObjective OutcomesSignificant improvement in BDCUNVANo significant difference in BCDVAInconclusive evidence for contrast sensitivityInconclusive evidence for glareSubjective OutcomesInconclusive evidence for visual satisfactionSignificant increase in glare/halosSignificant increase in freedom from spectaclesmoderatemoderatelowvery lowlowlow/moderatelow/moderateAccommodative vs. multifocal/monofocalInconclusive due to Insufficient limited evidence for any effectiveness outcomevery lowHydrophilic acrylic vs. other materials (hydrophobic acrylic, silicone)Significant increase in PCO scoreLowSharp edged compared to round edgedSignificant reduction in PCO scoreLowOne piece compared to three pieceNo significant difference in PCO scorelowHydrophobic acrylic compared to siliconeNo significant difference in PCO scoremoderateAspherical modified prolate anterior surface compared to sphericalNo significant difference in VASignificant reduction in contrast sensitivityvery lowvery lowBlue light filtering compared to non blue-light filteringNo significant difference in BCDVANo significant difference in contrast sensitivityNo significant difference in HRQLlowlowhigh/moderateBCDVA refers to best corrected distance visual acuity; BDCUNVA, best distance corrected unaided near visual acuity; HRQL, health related quality of life; PCO, posterior capsule opacification; VA, visual acuity.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.452
Threshold uncertainty score0.274

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.110
GPT teacher head0.366
Teacher spread0.256 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations18
Published2009
Admission routes1
Has abstractyes

Explore more

Same venuePubMedSame topicOphthalmology and Visual Impairment StudiesFrench-language works237,207