MétaCan
Menu
Back to cohort
Record W2981779034 · doi:10.1002/acm2.13280

Verification of the delivered patient radiation dose for non‐coplanar beam therapy

2021· article· en· W2981779034 on OpenAlexaff
Ivan Kutuzov, Timothy Van Beek, Boyd McCurdy

Bibliographic record

VenueJournal of Applied Clinical Medical Physics · 2021
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsUniversity of ManitobaCancerCare Manitoba
Fundersnot available
KeywordsImaging phantomRadiation treatment planningQuality assuranceComputer scienceNuclear medicineLinear particle acceleratorRadiation therapyBeam (structure)Medical physicsSimulationOpticsPhysicsMedicineRadiology

Abstract

fetched live from OpenAlex

PURPOSE: There is an increased interest in using non-coplanar beams for radiotherapy, including SBRT and SRS. This approach can significantly reduce doses to organs-at-risk, however, it requires stringent quality assurance, especially when a dynamic treatment couch is used. In this work, new functionality that allows using non-coplanar beam arrangements in addition to conventional coplanar beams was added and validated to the previously developed in vivo dose verification system. METHODS: The existing program code was modified to manage the additional treatment couch parameters: angle and positions. Ten non-coplanar test plans that use a static couch were created in the treatment planning system. Also, two plans that use a dynamic treatment couch were created and delivered using Varian Developer mode, since the treatment planning system does not support a dynamic couch. All non-coplanar test trajectories were delivered on a simple geometric phantom, using an Edge linear accelerator (Varian Medical Systems) with the megavoltage imager deployed and acquiring megavoltage transmission images that were used to calculate the delivered 3D dose distributions in the phantom with the updated dose calculation algorithm. The reconstructed dose distributions were compared using the 3D chi-comparison test with 2%/2mm tolerances to the corresponding reference dose distributions obtained from the treatment planning system. RESULTS: The chi-comparison test resulted in at least a 97.0% pass rate over the entire 3D volume for all tested trajectories. For static gantry, static couch non-coplanar fields, and non-coplanar arcs using dynamic couch the pass rates observed were at least 98%, while for the static couch, non-transverse coplanar arc fields, pass rates were at least 97%. CONCLUSIONS: A model-based 3D dose calculation algorithm has been extended and validated for a variety of non-coplanar beam trajectories of different complexities. This system can potentially be applied for quality assurance of treatment delivery systems that use complex, non-coplanar beam arrangements.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.006
Threshold uncertainty score0.021

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.004
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0060.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.336
Teacher spread0.315 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2021
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Applied Clinical Medical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207