Hydrus microstent implantation for surgical management of glaucoma: a review of design, efficacy and safety

2019· review· en· W2982052757 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueEye and Vision · 2019
Typereview
Languageen
FieldMedicine
TopicGlaucoma and retinal disorders
Canadian institutionsPrism Eye InstituteUniversity of Toronto
Fundersnot available
KeywordsMedicineGlaucoma surgeryGlaucomaSchlemm's canalTrabeculectomyTrabecular meshworkSafety profileSurgeryOphthalmologyAdverse effect

Abstract

fetched live from OpenAlex

With the advent of microinvasive glaucoma surgery (MIGS), the spectrum of modalities available to manage patients with this chronic and heterogeneous condition has broadened. Despite its novelty however, there has been a rapid evolution in the development of a multitude of devices, each targeting a structure along the aqueous drainage pathway. A growing body of evidence has demonstrated IOP and medication burden reduction, and a more favorable safety profile with MIGS procedures in contrast to traditional incisional surgeries. Among the array of MIGS, the Hydrus® Microstent (Ivantis, Inc., Irvine, CA) is a recent FDA approved device, designed to bypass the trabecular meshwork and provide a scaffold for Schlemm's canal. The objective of this article is to review the Hydrus from conception to clinical use, and present data on its efficacy and safety to date. The available literature has shown promise, however inherent to all novel devices, only long-term monitoring will ensure sustained IOP control and an acceptable safety profile. Surgical advancements in glaucoma have revolutionized the field, and continued research and development will establish these approaches in clinical treatment algorithms.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.700
Threshold uncertainty score0.500

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.035
GPT teacher head0.387
Teacher spread0.351 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it