Near-field Electrically Small Sensors Array with PCA for Microwave Breast Tumor Detection
Bibliographic record
Abstract
In this work, we propose the use of an electrically small dipole antenna arrays as a microwave sensor combined with a classification algorithm for near field microwave breast tumor detection. The proposed sensor has high sensitive to detect any changes or abnormality in the dielectric properties of the breast tissues. Detecting the existence of the breast tumors are expected by estimating the variations in the response of the reflection coefficient of the sensor. The Principle Component Analysis (PCA) feature extraction technique is applied to accentuate the variance in the sensor responses for both healthy and tumourous cases. We show that when a numerical realistic breast with and without tumor cells is placed in the near field of the sensor, the sensor is capable of detection tumorous with various sizes placed in single locations at two different stand off 5 mm and 10 mm respectively.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".