MétaCan
Menu
Back to cohort
Record W2983783940 · doi:10.1007/s00068-019-01263-6

Increased risk for postoperative periprosthetic fracture in hip fracture patients with the Exeter stem than the anatomic SP2 Lubinus stem

2019· article· en· W2983783940 on OpenAlexaboutno aff
Carl Mellner, Jabbar Mohammed, Magnus Larsson, Sandra Esberg, M. Szymański, Nils Hellström, Cecilia Chang, Hans E. Berg, Olof Sköldenberg, Björn Knutsson, Per Morberg, Sebastian Mukka

Bibliographic record

VenueEuropean Journal of Trauma and Emergency Surgery · 2019
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsnot available
Fundersnot available
KeywordsMedicinePeriprostheticIncidence (geometry)SurgeryCumulative incidenceCohortOrthopedic surgeryFemoral neckRetrospective cohort studyArthroplastyInternal medicineOsteoporosis

Abstract

fetched live from OpenAlex

BACKGROUND: The purpose of this study was to compare the cumulative incidence of postoperative periprosthetic fracture (PPF) in a cohort of femoral neck fracture (FNF) patients treated with two commonly used cemented stems: either a collarless, polished, tapered Exeter stem or the anatomic Lubinus SP2 stem. METHODS: In this retrospective multicenter cohort study of a consecutive series of patients, we included 2528 patients of age 60 years and above with an FNF who were treated with either hemiarthroplasty or total hip arthroplasty using either a polished tapered Exeter stem or an anatomic Lubinus SP2 stem. The incidence of PPF was assessed at a minimum of 2 years postoperatively. RESULTS: The incidence of PPF was assessed at a median follow-up of 47 months postoperatively. Thirty nine patients (1.5%) sustained a PPF at a median of 27 months (range 0-96 months) postoperatively. Two of the operatively treated fractures were Vancouver A (5%), 7 were Vancouver B1 (18%), 10 were Vancouver B2 (26%), 7 were Vancouver B3 (18%), and 13 were Vancouver C (32%). The cumulative incidence of PPF was 2.3% in the Exeter group compared with 0.7% in the SP2 group (p < 0.001). The HR was 5.4 (95% CI 2.4-12.5, p < 0.001), using the SP2 group as the denominator. CONCLUSIONS: The Exeter stem was associated with a higher risk for PPF than the Lubinus SP2 stem. We suggest that the tapered Exeter stem should be used with caution in the treatment of FNF. TRIAL REGISTRATION: The study was registered at clinicaltrials.gov (identifier: NCT03326271).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.036
Threshold uncertainty score0.391

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.213
Teacher spread0.202 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations26
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueEuropean Journal of Trauma and Emergency SurgerySame topicOrthopaedic implants and arthroplastyFrench-language works237,207