MétaCan
Menu
Back to cohort
Record W2987361869 · doi:10.1371/journal.pone.0224872

Evaluation of forearm vascular resistance during orthostatic stress: Velocity is proportional to flow and size doesn’t matter

2019· article· en· W2987361869 on OpenAlexafffund
Victoria E. Claydon, Jonathan P. Moore, Ernest R. Greene, Otto Appenzeller, R. Hainsworth

Bibliographic record

VenuePLoS ONE · 2019
Typearticle
Languageen
FieldMedicine
TopicCardiovascular Syncope and Autonomic Disorders
Canadian institutionsSimon Fraser University
FundersSimon Fraser UniversityUniversity of LeedsNew Mexico Health Enhancement and Marathon Clinics Research Foundation
KeywordsBrachial arteryVascular resistanceMedicinePresyncopeSupine positionBlood pressureOrthostatic vital signsHeart rateCardiologyForearmBlood flowInternal medicineAnesthesiaSurgery

Abstract

fetched live from OpenAlex

BACKGROUND: The upright posture imposes a significant challenge to blood pressure regulation that is compensated through baroreflex-mediated increases in heart rate and vascular resistance. Orthostatic cardiac responses are easily inferred from heart rate, but vascular resistance responses are harder to elucidate. One approach is to determine vascular resistance as arterial pressure/blood flow, where blood flow is inferred from ultrasound-based measurements of brachial blood velocity. This relies on the as yet unvalidated assumption that brachial artery diameter does not change during orthostatic stress, and so velocity is proportional to flow. It is also unknown whether the orthostatic vascular resistance response is related to initial blood vessel diameter. METHODS: We determined beat-to-beat heart rate (ECG), blood pressure (Portapres) and vascular resistance (Doppler ultrasound) during a combined orthostatic stress test (head-upright tilting and lower body negative pressure) continued until presyncope. Participants were 16 men (aged 38.4±2.3 years) who lived permanently at high altitude (4450m). RESULTS: The supine brachial diameter ranged from 2.9-5.6mm. Brachial diameter did not change during orthostatic stress (supine: 4.19±0.2mm; tilt: 4.20±0.2mm; -20mmHg lower body negative pressure: 4.19±0.2mm, p = 0.811). There was no significant correlation between supine brachial artery diameter and the maximum vascular resistance response (r = 0.323; p = 0.29). Forearm vascular resistance responses evaluated using brachial arterial flow and velocity were strongly correlated (r = 0.989, p<0.00001) and demonstrated high equivalency with minimal bias (-6.34±24.4%). DISCUSSION: During severe orthostatic stress the diameter of the brachial artery remains constant, supporting use of brachial velocity for accurate continuous non-invasive orthostatic vascular resistance responses. The magnitude of the orthostatic forearm vascular resistance response was unrelated to the baseline brachial arterial diameter, suggesting that upstream vessel size does not matter in the ability to mount a vasoconstrictor response to orthostasis.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.067
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.230
Teacher spread0.212 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2019
Admission routes2
Has abstractyes