MétaCan
Menu
Back to cohort

“Painless” Bone Marrow Aspiration by Slow Suctioning Does Not Affect Peripheral Blood Contamination of the Specimen: Randomized Prospective Crossover Trials

2008· article· en· W2988276663 on OpenAlexaboutno aff
Yuki Asano‐Mori, Shin‐ichiro Mori, Toshimitsu Ueki, Miwa Sakai, Takuya Yamashita, Kazuteru Ohashi, Hideki Akiyama, Hisashi Sakamaki

Bibliographic record

VenueBlood · 2008
Typearticle
Languageen
FieldMedicine
TopicHematological disorders and diagnostics
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineSyringeCrossover studyAnesthesiaSurgeryRandomized controlled trialVisual analogue scaleSuctionPulmonary aspirationPlacebo

Abstract

fetched live from OpenAlex

Abstract The pain during bone marrow aspiration (BMA) can be best explained by negative pressure inside the bone marrow cavity. Although most standard textbooks recommend rapid suctioning with high negative pressure to minimize peripheral blood contamination, this technique might be associated with more pain. To date, there is no evidence that rapid suctioning can reduce peripheral blood contamination. To find a technique that reduces pain without loss of specimen quality, we conducted two trials. The first was a randomized, crossover trial comparing slow aspiration with low negative pressure (L method) and rapid aspiration with high negative pressure (H method). To evaluate pain during the procedure, 49 patients with hematological malignancy who required BMA more than once were randomly assigned to receive either the first aspiration by the L method and the second by the H method or vice versa. Under local anesthesia, a 16-gauge BMA needle was inserted into the BM cavity. A 1-mL syringe (L method) or a 30-mL syringe (H method) was used to aspirate 0.5 mL of BM fluid. To ensure accuracy of aspiration volume in the H method, an extension tube was connected between the 30-mL syringe and needle, and clamped by forceps when the aspirated volume reached 0.5 mL. Pain during each procedure was evaluated using a visual analog scale (VAS), verbal descriptor scale (VDS), and McGill pain questionnaire (MPQ). In the first trial, repeated measures one-way analysis of variance design was used for serial measurement of pain, and the one-tailed Wilcoxon’s test was used to compare pain between the two groups. The second trial compared aspirate quality between the L and H methods. Sixteen allogeneic transplantation donors (median age, 33.5 years; range, 22 to 62 years), underwent the first puncture of the harvest procedure under general anesthesia. BMA was drawn simultaneously from the right and left posterior iliac crest with a 1-mL and a 30-mL syringe; the aspiration side and syringe size were randomized. Nucleated cell counts (NCC) of the BM specimens were determined by automated hematology analyses. The non-inferiority margin was defined as less than 25% on the basis of the absolute difference of NCC between the L and H methods. In the first trial, 34 of the 49 patients (67%; 21 men and 13 women; median age, 49 years; age range, 17 to 77 years) completed the study and provided VAS, VDS and MPQ score data after two consecutive BMA. Present pain intensity (PPI) score of the MPQ was significantly decreased with L method when compared with H method (median absolute difference 0, P=0.037) (Table 1). VAS score and total pain rating index (PRI) of the MPQ were also lower with the L method (median absolute differences −0.6 and −0.5), although these results did not reach statistical significance. There was no significant ordinal interaction in repeated measurement of any scores except the affective-PRI of the MPQ, which was significantly higher at the first aspiration, regardless of the negative pressure intensity (P=0.024). In the second trial, the geometric mean of NCC with the L method was non-inferior to the mean with the H method (P=0.025) (Table 2). These findings indicated that BMA with low negative pressure tended to be less painful, while maintaining specimen quality. There remains difficulty in evaluating the impact of psychological factors on the results. Nonetheless, on the basis of our results we recommend suctioning slowly with low negative pressure using a small syringe in order to reduce pain during BMA. Table 1 L method H method P-value median (range) median (range) VDS 1 (0 to 3) 1 (0 to 3) 0.212 VAS 2.2 (0 to 8.4) 3.2 (0 to 9.0) 0.055 MPQ PRI-S 3 (0 to 16) 4 (0 to 30) 0.080 PRI-A 0 (0 to 7) 0 (0 to 9) 0.192 PRI-E 0 (0 to 4) 0 (0 to 4) 0.414 F’RI-M 2 (0 to 11) 3 (0 to 11) 0.093 PRI-T 6 (0 to 32) 7.5 (0 to 53) 0.063 PPI 1 (0 to 4) 1 (0 to 5) 0.037 Table 2 L method H method P-value Genomic mean of NCC (×104/μL) (95%IC) 6.6 (4.6–9.5) 7.8 (5.9– 10.4) 0.025

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.008
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.291
Threshold uncertainty score0.951

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.008
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.269
Teacher spread0.250 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2008
Admission routes1
Has abstractyes

Explore more

Same venueBloodSame topicHematological disorders and diagnosticsFrench-language works237,207