MétaCan
Menu
← Back to cohort
Record W2988840507 · doi:10.1111/cid.12868

In vitro comparative analysis of two resonance frequency measurement devices: Osstell implant stability coefficient and Penguin resonance frequency analysis

2019· article· en· W2988840507 on OpenAlexvenueno aff
Mariano Herrero‐Climent, Artur Falcão, Paula López‐Jarana, Carmen María Díaz-Castro, Blanca Ríos‐Carrasco, JV Ríos-Santos

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2019
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
Fundersnot available
KeywordsResonance frequency analysisRepeatabilityIntraclass correlationImplant stability quotientTransducerImplantReproducibilityMaterials scienceBiomedical engineeringDentistryOrthodonticsOsseointegrationMathematicsMedicineAcousticsPhysicsSurgeryStatistics

Abstract

fetched live from OpenAlex

Adequate implant stability is an essential requirement. The introduction of the Penguin resonance frequency analysis raises some questions regarding its reliability, reproducibility, and repeatability as well as how it compares to the older Osstell device. PURPOSE: To assess the newer Penguin implant stability coefficient (ISQ) device (vs the Osstell device). MATERIALS AND METHODS: A total of 120 implants were used, divided into four groups (A, B, C, and D) (according to design) and placed in fresh bovine bone. Consecutive measurements were made with both devices (Penguin/Osstell) with their respective transducers. Then, the ISQ values were measured with the Penguin device using the Osstell transducer, and vice-versa. RESULTS: The mean insertion torque (N/cm) values for the implants were as follows: Group A = 24.7 ± 9.4; Group B = 25.6 ± 9.7; Group C = 28.7 ± 7.9; Group D = 19.1 ± 5.5. The mean ISQ values for the entire sample were as follows: Penguin 67.7 ± 6.1 and Osstell 68.5 ± 9.6. The ISQ value measured with the Penguin device using a SmartPeg transducer was 67.0 ± 8.0, and that for the Osstell device using a MultiPeg transducer was 68.3 ± 7.5. The intraclass correlation coefficient (ICC) was calculated for the ISQ values obtained from both devices and was >0.90 for all transducers. When the ICC transducers were interchanged, the values were <0.77. CONCLUSIONS: Both ISQ devices allow for reliable and repeatable measurement of implant stability; however, the use of each device-specific transducer is recommended.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.013

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.166
GPT teacher head0.460
Teacher spread0.294 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations19
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related Research→Same topicDental Implant Techniques and Outcomes→French-language works237,207→