MétaCan
Menu
Back to cohort
Record W2990128034 · doi:10.1093/jcag/gwz032

Canadian Association of Gastroenterology Communique: After-Hours Endoscopy Cart

2019· article· en· W2990128034 on OpenAlexaffabout
Mandip Rai, Mary Cooper, Scott Shulman, Dan Kottachchi, Sandra Nelles, Mark MacMillan, Steven J. Heitman, Alan Barkun, Frances Tse, Lawrence Hookey

Bibliographic record

VenueJournal of the Canadian Association of Gastroenterology · 2019
Typearticle
Languageen
FieldMedicine
TopicNausea and vomiting management
Canadian institutionsMcGill University Health CentreUniversity of CalgaryMemorial University of NewfoundlandDalhousie UniversityTrillium Health CentreNOSM UniversityGuelph General HospitalThunder Bay Regional Health Sciences CentreMcMaster UniversityQueen's University
FundersBoston Scientific Corporation
KeywordsMedicineEndoscopyTherapeutic endoscopyColonoscopyCartSurgeryLithotomy positionGeneral surgeryMedical physicsInternal medicinePathologyColorectal cancer

Abstract

fetched live from OpenAlex

BACKGROUND: Endoscopic procedures performed after-hours often require therapeutic interventions that are technically demanding for the endoscopist. The aim of this position paper is to provide guidance on the minimum standard of equipment that should be available on a mobile endoscopy cart for provision of a safe and effective after-hours emergency endoscopy service. The guidance is based on consensus among academic and community gastroenterologists in Canada. METHODS: A modified Delphi process was used to establish consensus among 9 participants. A list of statements was prepared by an expert panel of endoscopists. The statements were divided into three broad sections for what should be on an after-hours endoscopy cart including medications, nonendoscopic tools and therapeutic/diagnostic equipment. Consensus for being on the endoscopy cart was achieved when 75% or more of voting members indicated 'agree'. RESULTS: For nonendoscopic tools, there was agreement for having sterile saline, sterile water, endoscope lubricant, various syringes, bite blocks (paediatric and adult size), a water pump with foot peddle, formalin jars for biopsy specimens, digital photo and printing capability and an overtube. For medications, there was agreement for having hyoscine butylbromide and epinephrine on the cart. For therapeutic/diagnostic tools, there was agreement for having biopsy forceps (standard and jumbo), polypectomy snares, sclerotherapy needles and agent (for a variceal bleed), band ligation kit, multipolar electrocautery probes, heater probe catheter, endoscopic clips, hemostatic powder and retrieval devices. INTERPRETATION: This position paper provides guidance on the minimum standard of items that should be on an after-hours endoscopy cart. Standardization of equipment may help improve safety and quality of after-hours endoscopic procedures.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.816
Threshold uncertainty score0.998

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.228
Teacher spread0.222 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2019
Admission routes2
Has abstractyes

Explore more

Same venueJournal of the Canadian Association of GastroenterologySame topicNausea and vomiting managementFrench-language works237,207