MétaCan
Menu
Back to cohort
Record W2991319871 · doi:10.14740/cr949

The Safety and Efficacy of Guidezilla Catheter (Mother-in-Child Catheter) in Complex Coronary Interventions: An Observational Study

2019· article· en· W2991319871 on OpenAlex
Prakash Kumar, Puneet Aggarwal, Santosh Kumar Sinha, Dibbendu Khanra, Mahmodullah Razi, Awadhesh Kumar Sharma, Ramesh Thakur, Umeshwar Pandey, Vinay Krishna

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

venuePublished in a venue whose home country is Canada.
no affNo Canadian affiliation: this work is invisible to an affiliation-only frame.
No Canadian affiliation. An affiliation-only frame, the usual design, would never have seen this work. It is one of the works that make the case for inverting the frame.

Bibliographic record

VenueCardiology Research · 2019
Typearticle
Languageen
FieldMedicine
TopicVascular Procedures and Complications
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineCatheterPercutaneous coronary interventionCircumflexLesionConventional PCISurgeryCardiologyRight coronary arteryInternal medicineArteryMyocardial infarctionCoronary angiography

Abstract

fetched live from OpenAlex

BACKGROUND: Lesion characteristics (anatomy, calcification, tortuosity and angulation), vessel morphology, and lack of support add complexity of coronary intervention. Guidezilla catheter, acting as an extension of guide catheter system (mother-in-child catheter), helps to overcome these complexities by enhancing backup during complex intervention. METHODS: The present retrospective, single-center study included 13,157 consecutive patients who underwent percutaneous coronary intervention (PCI) through both transfemoral and transradial routes from January 2015 to July 2019 at LPS Institute of Cardiology, G.S.V.M. Medical College, Kanpur, Uttar Pradesh, India among which Guidezilla™ catheter (Boston Scientific, Natick, MA, USA) was used in 156 patients. Study endpoints were target lesion crossing, procedural success, and complications. The clinical, angiographic and procedural data of all 156 patients were evaluated to assess safety and efficacy of Guidezilla extension catheter (GEC). RESULTS: The mean age of the enrolled patients was 61.2 ± 8.67 years. Type-C lesion was commonest (69.9%) followed by B2 (22.4%) and B1 (7.7%). The commonest indication for its use was tortuosity (30.1%) followed by calcification (21.1%), angulation (18.8%), chronic total occlusion (17.9%), distally located lesion (8.3%), and anomalous origin of vessel in 3.8%. The right coronary artery (39.2%) was most commonly intervened artery followed by left anterior descending (LAD) (30.8%), left circumflex (LCX) (19.9%), multivessels (7.6%), and saphenous vein graft in 2.5%. The mean depth of intubation was 4.2 ± 1.9 cm. Mean diameter of stents was 34.2 ± 14.4 mm while mean length of stents was 31.2 ± 10.2 mm. Lesions were modified using aggressive pre-dilatation in 87.8%, followed by cutting balloon in 10.9%. GEC was delivered across the lesion using buddy wire technique (9.6%), balloon-assisted tracking (BAT) in 30.1%, and balloon-assisted sliding and tracking (BLAST) in 4.5% of patients. Stent implantation was successful in 151 out of 156 patients with success rate of 96.7%. Overall failure rate was 3.3% which was contributed by extreme tortuosity, angulation, and severe calcification. Guidezilla-associated procedural complication (dissection, stent dislodgement, shaft breakage) were reported in three patients (1.9%) who were successfully managed. CONCLUSION: s Guidezilla system acting as mother-in-child extension catheter is a safe and effective tool which provides additional backup support and increases success rate of PCI for complex coronary lesions.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.005
Threshold uncertainty score0.235

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.278
GPT teacher head0.462
Teacher spread0.184 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it