The Safety and Efficacy of Guidezilla Catheter (Mother-in-Child Catheter) in Complex Coronary Interventions: An Observational Study
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
BACKGROUND: Lesion characteristics (anatomy, calcification, tortuosity and angulation), vessel morphology, and lack of support add complexity of coronary intervention. Guidezilla catheter, acting as an extension of guide catheter system (mother-in-child catheter), helps to overcome these complexities by enhancing backup during complex intervention. METHODS: The present retrospective, single-center study included 13,157 consecutive patients who underwent percutaneous coronary intervention (PCI) through both transfemoral and transradial routes from January 2015 to July 2019 at LPS Institute of Cardiology, G.S.V.M. Medical College, Kanpur, Uttar Pradesh, India among which Guidezilla™ catheter (Boston Scientific, Natick, MA, USA) was used in 156 patients. Study endpoints were target lesion crossing, procedural success, and complications. The clinical, angiographic and procedural data of all 156 patients were evaluated to assess safety and efficacy of Guidezilla extension catheter (GEC). RESULTS: The mean age of the enrolled patients was 61.2 ± 8.67 years. Type-C lesion was commonest (69.9%) followed by B2 (22.4%) and B1 (7.7%). The commonest indication for its use was tortuosity (30.1%) followed by calcification (21.1%), angulation (18.8%), chronic total occlusion (17.9%), distally located lesion (8.3%), and anomalous origin of vessel in 3.8%. The right coronary artery (39.2%) was most commonly intervened artery followed by left anterior descending (LAD) (30.8%), left circumflex (LCX) (19.9%), multivessels (7.6%), and saphenous vein graft in 2.5%. The mean depth of intubation was 4.2 ± 1.9 cm. Mean diameter of stents was 34.2 ± 14.4 mm while mean length of stents was 31.2 ± 10.2 mm. Lesions were modified using aggressive pre-dilatation in 87.8%, followed by cutting balloon in 10.9%. GEC was delivered across the lesion using buddy wire technique (9.6%), balloon-assisted tracking (BAT) in 30.1%, and balloon-assisted sliding and tracking (BLAST) in 4.5% of patients. Stent implantation was successful in 151 out of 156 patients with success rate of 96.7%. Overall failure rate was 3.3% which was contributed by extreme tortuosity, angulation, and severe calcification. Guidezilla-associated procedural complication (dissection, stent dislodgement, shaft breakage) were reported in three patients (1.9%) who were successfully managed. CONCLUSION: s Guidezilla system acting as mother-in-child extension catheter is a safe and effective tool which provides additional backup support and increases success rate of PCI for complex coronary lesions.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.002 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it