MétaCan
Menu
Back to cohort
Record W2991631491 · doi:10.1177/1120700019887362

Intraoperative radiation exposure in hip arthroscopy: a systematic review

2019· review· en· W2991631491 on OpenAlexaff
Ajay Shah, Mohammed Nassri, Jeffrey Kay, Nicole Simunovic, Vasco Mascarenhas, Tony Andrade, Óliver Marín-Peña, Olufemi R. Ayeni

Bibliographic record

VenueHip International · 2019
Typereview
Languageen
FieldMedicine
TopicRadiation Dose and Imaging
Canadian institutionsImpactMcMaster University
Fundersnot available
KeywordsMedicineFluoroscopyRadiation exposureHip arthroscopyPerioperativeDose area productNuclear medicineIonizing radiationRadiation doseEffective dose (radiation)RadiologySurgeryArthroscopyIrradiation

Abstract

fetched live from OpenAlex

Fluoroscopy is used in hip arthroscopy (HA) for portal placement, instrument localisation, and guidance in bony resection. The recent increase in arthroscopic hip procedures may place patients and surgeons at risk for increased radiation exposure and radiation-induced complications. The purpose of the current systematic review was to assess intraoperative radiation exposure in HA. The systematic review was conducted according to PRISMA guidelines; inclusion criteria were studies assessing radiation exposure in HA. 9 studies including 994 patients were included. Mean age was 38.6 years and 48% (436 of 906) were female. Mean time of fluoroscopy exposure was 0.58 minutes. Dose area product was 129.5 cGycm 2 . Mean intraoperative absorbed radiation dose studies was 12.6 mGy. Mean intraoperative effective dose was 0.48 mSv. The mean occupational exposure to the surgeon per case was 0.0031 mSv. Higher patient body mass index (BMI) correlated to greater patient effective and cumulative dose ( p < 0.05, r = 0.404), and greater occupational exposure ( p < 0.001, r = 0.460). Increasing surgeon experience decreased fluoroscopy time ( p = 0.039) and radiation dose ( p = 0.002). Radiation dose and effective dose were well under the thresholds for deterministic effects (2 Gy) and annual radiation exposure for occupational workers (20 mSv). Intraoperative radiation exposure to patients and surgeons is within acceptable annual radiation limits. Ensuring careful selection of perioperative imaging modalities, proper protective shielding, specifically the use of leaded eyeglasses, and optimal C-arm positioning are key strategies to reduce radiation exposure to patients and surgeons alike.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Insufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Systematic review · Consensus signal: Systematic review
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.315
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0020.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.047
GPT teacher head0.381
Teacher spread0.334 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designSystematic review
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations10
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueHip InternationalSame topicRadiation Dose and ImagingFrench-language works237,207