MétaCan
Menu
Back to cohort
Record W2995891278

"Sensor-in-fibre" optical probes for molecular sensing in the gastrointestinal tract of murine models

2019· article· en· W2995891278 on OpenAlexaboutno aff
Victor Azzi

Bibliographic record

VenueCorpus Université Laval (Université Laval) · 2019
Typearticle
Languageen
FieldChemical Engineering
TopicAnalytical Chemistry and Sensors
Canadian institutionsnot available
Fundersnot available
KeywordsGastrointestinal tractOptical fiberRemote sensingComputer scienceComputational biologyChemistryBiologyOpticsPhysicsGeologyBiochemistry
DOInot available

Abstract

fetched live from OpenAlex

L’obésité et les maladies cardiométaboliques sont des problèmes de santé publique dans les populations nordiques du Canada ainsi qu’à travers le monde. Il est actuellement proposé que l’augmentation de ces désordres est en partie causée par divers facteurs environnementaux qui génèrent des changements importants du microbiote intestinal. Cette communauté microbienne qui peuple notre tractus gastrointestinal joue un rôle clé dans le métabolisme de nutriments, mais peut aussi avoir des effets néfastes lorsque son équilibre avec l’hôte est perturbé. Cette compréhension a mis en évidence le manque d’outils prédictifs permettant un diagnostic rapide et efficace dans le domaine biomédical. L’analyse actuelle du microbiote est réalisée à posteriori au niveau des selles, ce qui requiert du personnel hautement qualifié de même que des procédures longues et dispendieuses. L’objectif de ce projet est de concevoir un capteur optique qui, une fois implanté dans l’intestin, permettra de détecter en temps réel des biomarqueurs clés produit par le microbiome intestinal. Dans le cadre d’une preuve de concept, une architecture fibrée simple permettant de mesurer quantitativement des variations de pH est démontrée. Contrairement aux capteurs fibrés traditionnels, la sonde optique de ce projet exploite l’onde évanescente générée sur la périphérie de l’interface pour exciter des nanomatériaux greffés dont les propriétés de fluorescence varient selon leur environnement chimique. Les mesures sont possibles grâce à un système optique mobile contrôlé par un logiciel convivial qui permet à un utilisateur nonexpert d’utiliser l’appareil. Les résultats confirment qu’avec un étalonnage préalable il est possible avec cette sonde modèle de prendre des mesures quantitatives du pH en temps réel in vitro. Les expériences préliminaires suggèrent que la sonde permet aussi de mesurer le pH en temps réel dans l’intestin in vivo.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.187
Teacher spread0.178 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueCorpus Université Laval (Université Laval)Same topicAnalytical Chemistry and SensorsFrench-language works237,207