MétaCan
Menu
← Back to cohort
Record W2996558779 · doi:10.1111/hdi.12808

Nocturnal home hemodialysis with low‐flow dialysate: Retrospective analysis of the first European patients

2019· article· en· W2996558779 on OpenAlexvenueno aff
Venkat Gangaram, Mari Vilpakka, Éric Goffin, Eric D. Weinhandl, Kristine Kubisiak, Natalie Borman

Bibliographic record

VenueHemodialysis International · 2019
Typearticle
Languageen
FieldMedicine
TopicDialysis and Renal Disease Management
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineHemodialysisDialysisHome hemodialysisTolerabilityNocturnalDemographicsAdverse effectRetrospective cohort studyRegimenEmergency medicineSurgeryPhysical therapyInternal medicine

Abstract

fetched live from OpenAlex

INTRODUCTION: Despite mounting evidence that increased frequency and duration of hemodialysis (HD) improves outcomes, less than 1% of HD patients worldwide receive nocturnal hemodialysis (NHD). Many perceived barriers exist to providing NHD and increasing its provision. METHODS: A retrospective analysis of nocturnal therapy using a low-flow dialysate system in 4 European centers for a minimum of 12 months, with data collected on patient demographics, training times, safety features, medications, and biochemical parameters at baseline and at 6 and 12 months. FINDINGS: Data were collected on 21 patients, with 12-month analysis available for 20 patients. Mean dialysis duration was 28 hours per week, with most dialysis on an alternate night regimen using 50-60 L of dialysate per session. All vascular access types were represented, and low molecular weight heparin was used as a bolus. All biochemical parameters met European standards, with a trend for improvement in standardized Kt/V, phosphate, hemoglobin, and albumin. There was a significant reduction in phosphate binder usage and a reduction in blood pressure medication. Training time was 9.6 sessions for independence at home, with 2 additional sessions to transition to NHD. Additional safety features included an alarmed drip tray under the cycler and moisture sensors under the venous needle (all patients used dual-cannulation technique). No patient safety events were reported. DISCUSSION: These data support the use of a low-flow dialysate system for provision of NHD at home. Biochemical parameters were good, medication burden was reduced at 12 months, and all patients received more than double the duration of HD provided in standard in-center units. While patient numbers were small, low-flow dialysis in this cohort was both effective and safe. Use of this alternative HD system could reduce some of the barriers to NHD, increasing the uptake of therapy in Europe, and improving long-term patient outcomes.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.002
Science and technology studies0.0010.000
Scholarly communication0.0010.001
Open science0.0000.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.004
GPT teacher head0.208
Teacher spread0.204 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueHemodialysis International→Same topicDialysis and Renal Disease Management→French-language works237,207→