MétaCan
Menu
Back to cohort
Record W2996693786 · doi:10.1183/23120541.00160-2019

Comparison of oscillometry devices using active mechanical test loads

2019· article· en· W2996693786 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.

Bibliographic record

VenueERJ Open Research · 2019
Typearticle
Languageen
FieldMedicine
TopicChronic Obstructive Pulmonary Disease (COPD) Research
Canadian institutionsUniversité de MontréalCentre Intégré Universitaire de Santé et de Services Sociaux du Centre-Sud-de-l'Île-de-MontréalMcGill University Health Centre
FundersSzegedi TudományegyetemUniversity of Cape TownDalhousie UniversityMcGill UniversityUniversità degli Studi di MilanoUniversità degli Studi di TorinoNational Research, Development and Innovation OfficeSemmelweis Egyetem
KeywordsMouthpieceReactanceInertanceMedicineBreathingAcousticsBiomedical engineeringTube (container)Materials scienceAnesthesiaElectrical engineeringEngineeringComposite materialVoltagePhysics

Abstract

fetched live from OpenAlex

Noninvasiveness, low cooperation demand and the potential for detailed physiological characterisation have promoted the use of oscillometry in the assessment of lung function. However, concerns have been raised about the comparability of measurement outcomes delivered by the different oscillometry devices. The present study compares the performances of oscillometers in the measurement of mechanical test loads with and without simulated breathing. Six devices (five were commercially available and one was custom made) were tested with mechanical test loads combining resistors ( R ), gas compliances ( C ) and a tube inertance ( L ), to mimic respiratory resistance ( R rs ) and reactance ( X rs ) spectra encountered in clinical practice. A ventilator was used to simulate breathing at tidal volumes of 300 and 700 mL at frequencies of 30 and 15 min −1 , respectively. Measurements were evaluated in terms of R , C , L , resonance frequency ( f res ), reactance area ( A X ) and resistance change between 5 and 20 or 19 Hz ( R 5–20(19) ). Increasing test loads caused progressive deviations in R rs and X rs from calculated values at various degrees in the different oscillometers. While mean values of R rs were recovered acceptably, some devices exhibited serious distortions in the frequency dependences of R rs and X rs , leading to large errors in C , L , f res , A X and R 5–20(19) . The results were largely independent of the simulated breathing. Simplistic calibration procedures and mouthpiece corrections, in addition to unknown instrumental and signal processing factors, may be responsible for the large differences in oscillometry measures. Rigorous testing and ongoing harmonisation efforts are necessary to better exploit the diagnostic and scientific potential of oscillometry.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.076
Threshold uncertainty score0.999

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.002
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.002
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0050.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.182
GPT teacher head0.502
Teacher spread0.320 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it