Seizure Detection Algorithms in Critically Ill Children: A Comparative Evaluation
Bibliographic record
Abstract
OBJECTIVES: To evaluate the performance of commercially available seizure detection algorithms in critically ill children. DESIGN: Diagnostic accuracy comparison between commercially available seizure detection algorithms referenced to electroencephalography experts using quantitative electroencephalography trends. SETTING: Multispecialty quaternary children's hospital in Canada. SUBJECTS: Critically ill children undergoing electroencephalography monitoring. INTERVENTIONS: Continuous raw electroencephalography recordings (n = 19) were analyzed by a neurophysiologist to identify seizures. Those recordings were then converted to quantitative electroencephalography displays (amplitude-integrated electroencephalography and color density spectral array) and evaluated by six independent electroencephalography experts to determine the sensitivity and specificity of the amplitude-integrated electroencephalography and color density spectral array displays for seizure identification in comparison to expert interpretation of raw electroencephalography data. Those evaluations were then compared with four commercial seizure detection algorithms: ICTA-S (Stellate Harmonie Version 7; Natus Medical, San Carlos, CA), NB (Stellate Harmonie Version 7; Natus Medical), Persyst 11 (Persyst Development, Prescott, AZ), and Persyst 13 (Persyst Development) to determine sensitivity and specificity in comparison to amplitude-integrated electroencephalography and color density spectral array. MEASUREMENTS AND MAIN RESULTS: Of the 379 seizures identified on raw electroencephalography, ICTA-S detected 36.9%, NB detected 92.3%, Persyst 11 detected 75.9%, and Persyst 13 detected 74.4%, whereas electroencephalography experts identified 76.5% of seizures using color density spectral array and 73.7% using amplitude-integrated electroencephalography. Daily false-positive rates averaged across all recordings were 4.7 with ICTA-S, 126.3 with NB, 5.1 with Persyst 11, 15.5 with Persyst 13, 1.7 with color density spectral array, and 1.5 with amplitude-integrated electroencephalography. Both Persyst 11 and Persyst 13 had sensitivity comparable to that of electroencephalography experts using amplitude-integrated electroencephalography and color density spectral array. Although Persyst 13 displayed the highest sensitivity for seizure count and seizure burden detected, Persyst 11 exhibited the best trade-off between sensitivity and false-positive rate among all seizure detection algorithms. CONCLUSIONS: Some commercially available seizure detection algorithms demonstrate performance for seizure detection that is comparable to that of electroencephalography experts using quantitative electroencephalography displays. These algorithms may have utility as early warning systems that prompt review of quantitative electroencephalography or raw electroencephalography tracings, potentially leading to more timely seizure identification in critically ill patients.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.007 | 0.035 |
| Meta-epidemiology (narrow) | 0.001 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.001 |
| Bibliometrics | 0.002 | 0.001 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.001 | 0.001 |
| Open science | 0.001 | 0.001 |
| Research integrity | 0.001 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".