MétaCan
Menu
Back to cohort
Record W2999166681 · doi:10.1364/ol.383238

Chalcogenide microfiber-assisted silica microfiber for ultrasound detection

2020· article· lv· W2999166681 on OpenAlexafffund
Huibo Fan, Liang Chen, Xiaoyi Bao

Bibliographic record

VenueOptics Letters · 2020
Typearticle
Languagelv
FieldEngineering
TopicPhotoacoustic and Ultrasonic Imaging
Canadian institutionsUniversity of Ottawa
FundersNatural Sciences and Engineering Research Council of CanadaCanada Research Chairs
KeywordsMicrofiberMaterials scienceUltrasoundOpticsAnalytical Chemistry (journal)ChemistryPhysicsAcousticsComposite materialChromatography

Abstract

fetched live from OpenAlex

An ultra-compact ultrasound sensor with a chalcogenide (ChG) microfiber and a silica microfiber is fabricated. It can detect the ultrasound wave generated by a piezoelectric transducer peaked at 3.7 MHz. The sensor shows the broadband ultrasound frequency response with a high signal-to-noise ratio (SNR), owing to the high refractive index and small Young’s modulus of ChG material. A ChG ( <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline"> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:msub> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mi mathvariant="normal">A</mml:mi> <mml:mi mathvariant="normal">s</mml:mi> </mml:mrow> <mml:mn>2</mml:mn> </mml:msub> </mml:mrow> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:msub> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mi mathvariant="normal">S</mml:mi> <mml:mi mathvariant="normal">e</mml:mi> </mml:mrow> <mml:mn>3</mml:mn> </mml:msub> </mml:mrow> </mml:math> ) microfiber of 2 µm diameter is adhered to the surface of a silica microfiber with a diameter of 5 µm via Van der Waals force; the transmission spectrum has high contrast due to multi-mode interference in this hybrid structure. The SNR response could be up to 70 dB, especially at low frequency due to the soft ChG microfiber as a sensing unit to magnify the ultrasound signal, along with an SNR over 12 dB at ultrasound of 31.2 MHz. As a comparison, a silica taper with the same size as the ChG microfiber is also placed on the silica microfiber with a diameter of 5 µm to detect an ultrasound signal from 18 kHz to 9.4 MHz with an SNR lower than that based on the ChG microfiber up to 38.8 dB, showing the high sensitivity of the ChG microfiber.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.469
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.212
Teacher spread0.196 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations19
Published2020
Admission routes2
Has abstractyes

Explore more

Same venueOptics LettersSame topicPhotoacoustic and Ultrasonic ImagingFrench-language works237,207