MétaCan
Menu
Back to cohort
Record W3000555258 · doi:10.1109/tuffc.2020.2965767

Superharmonic Ultrasound for Motion-Independent Localization Microscopy: Applications to Microvascular Imaging From Low to High Flow Rates

2020· article· en· W3000555258 on OpenAlexafffund
Thomas M. Kierski, David Espíndola, Isabel G. Newsome, Emmanuel Chérin, Jianhua Yin, F. Stuart Foster, Christine Démoré, Gianmarco Pinton, Paul A. Dayton

Bibliographic record

VenueIEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · 2020
Typearticle
Languageen
FieldEngineering
TopicPhotoacoustic and Ultrasonic Imaging
Canadian institutionsUniversity of TorontoSunnybrook Hospital
FundersNational Institute of Biomedical Imaging and BioengineeringNational Cancer InstituteNational Heart, Lung, and Blood InstituteCanadian Institutes of Health ResearchNational Institutes of Health
KeywordsSubharmonic functionUltrasoundMicroscopyUltrasonic imagingMaterials scienceUltrasound imagingMotion (physics)Biomedical engineeringAcousticsPhysicsOpticsMedicineMathematicsClassical mechanics

Abstract

fetched live from OpenAlex

Recent advances in high frame rate biomedical ultrasound have led to the development of ultrasound localization microscopy (ULM), a method of imaging microbubble (MB) contrast agents beyond the diffraction limit of conventional coherent imaging techniques. By localizing and tracking the positions of thousands of individual MBs, ultrahigh resolution vascular maps are generated which can be further analyzed to study disease. Isolating bubble echoes from tissue signal is a key requirement for super-resolution imaging which relies on the spatiotemporal separability and localization of the bubble signals. To date, this has been accomplished either during acquisition using contrast imaging sequences or post-beamforming by applying a spatiotemporal filter to the B-mode images. Superharmonic imaging (SHI) is another contrast imaging method that separates bubbles from tissue based on their strongly nonlinear acoustic properties. This approach is highly sensitive, and, unlike spatiotemporal filters, it does not require decorrelation of contrast agent signals. Since this superharmonic method does not rely on bubble velocity, it can detect completely stationary and moving bubbles alike. In this work, we apply SHI to ULM and demonstrate an average improvement in SNR of 10.3-dB in vitro when compared with the standard singular value decomposition filter approach and an increase in SNR at low flow ( [Formula: see text]/frame) from 5 to 16.5 dB. Additionally, we apply this method to imaging a rodent kidney in vivo and measure vessels as small as [Formula: see text] in diameter after motion correction.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.965
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.001
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.211
Teacher spread0.205 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations42
Published2020
Admission routes2
Has abstractyes

Explore more

Same venueIEEE Transactions on Ultrasonics Ferroelectrics and Frequency ControlSame topicPhotoacoustic and Ultrasonic ImagingFrench-language works237,207