MétaCan
Menu
Back to cohort
Record W3002847856 · doi:10.1115/1.4046084

Exergy Analysis of Heat Recovery Steam Generator: Effects of Supplementary Firing and Desuperheater

2020· article· en· W3002847856 on OpenAlexaff
Hanieh Khalili Param, Ofelia A. Jianu

Bibliographic record

VenueJournal of Energy Resources Technology · 2020
Typearticle
Languageen
FieldEngineering
TopicThermodynamic and Exergetic Analyses of Power and Cooling Systems
Canadian institutionsUniversity of Windsor
Fundersnot available
KeywordsExergySuperheaterCombustorHeat recovery steam generatorExergy efficiencyHeat exchangerFlue gasWaste heat recovery unitEnvironmental scienceBoiler (water heating)Waste managementCombustionEngineeringChemistryThermal power stationMechanical engineering

Abstract

fetched live from OpenAlex

Abstract Comprehensive exergy analysis of a heat recovery steam generator (HRSG) with two levels of delivered pressure is presented. The effects of supplementary firing as well as desuperheater set-point are considered to evaluate the exergy destruction of HRSG components. Burner firing rate is limited to a value that corresponds to the maximum allowable temperature of tube metal of high-pressure (HP) superheater. According to the exergy analysis performed in the current study, the exergy efficiency of HRSG is about 80% which means 20% of flue gas exergy (entering HRSG) is dissipated by HRSG destruction (∼14%) and stack exergy loss (∼6%). The stack exergy loss drops continuously as supplementary firing raises. It has also been determined that increasing the rate of supplementary firing boosts the exergy efficiency in the absence of water spray and reduces it when desuperheater is working. In addition, the exergy delivered to steam turbine shows a linear growth with burner heat while it is hardly affected by the set-point of desuperheater. Also, it is found that exergy loss through the stack is not sensitive to desuperheater set-point while it is on the decrease as burner duty raises. HP steam flow will raise with increasing the firing and/or decreasing the desuperheater set-point. HP evaporator has the most contribution in exergy destruction among HRSG components (∼40%), whereas HP superheater and desuperheater are components with a maximum sensitivity of exergy destruction to the amount of water spray.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.161
Threshold uncertainty score0.499

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.003
GPT teacher head0.180
Teacher spread0.176 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Energy Resources TechnologySame topicThermodynamic and Exergetic Analyses of Power and Cooling SystemsFrench-language works237,207