MétaCan
Menu
Back to cohort
Record W3003643612 · doi:10.1159/000505261

Implantation of a Coronary Sinus Reducer to Treat Refractory Angina in a 38-Year-Old with an Anomalous Left Coronary Artery and No Revascularization Options

2020· article· en· W3003643612 on OpenAlex
Kevin Cheng, Ranil de Silva

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

aboutThe title or abstract carries a Canadian signal from the geographic lexicon.
no affNo Canadian affiliation: this work is invisible to an affiliation-only frame.
No Canadian affiliation. An affiliation-only frame, the usual design, would never have seen this work. It is one of the works that make the case for inverting the frame.

Bibliographic record

VenueCardiology · 2020
Typearticle
Languageen
FieldMedicine
TopicCoronary Artery Anomalies
Canadian institutionsnot available
FundersNational Institute for Health and Care Research
KeywordsMedicineCardiologyAnginaInternal medicineCanadian Cardiovascular SocietyContext (archaeology)RevascularizationCoronary sinusArteryCoronary artery diseaseStentMyocardial infarction

Abstract

fetched live from OpenAlex

A 38-year-old female with anomalous left coronary artery from the pulmonary artery presented with refractory angina (Canadian Cardiovascular Society [CCS] class 4). Having failed two previous internal mammary artery grafts to the left anterior descending artery and with no percutaneous revascularization options, she underwent coronary sinus reducer implantation, which improved her symptoms (CCS 0), quality of life, and corresponded to an improvement in ischemia on myocardial perfusion scanning. This case report describes an unusual case of refractory angina in the context of congenital heart disease, illustrates the benefit of this novel hourglass-shaped stent in improving ischemia, quality of life, depression and anxiety, and highlights the importance of managing these patients in multidisciplinary teams.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.055
Threshold uncertainty score0.626

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.245
Teacher spread0.230 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it