Clinical comparison of the positron emission tracking (PeTrack) algorithm with the real‐time position management system for respiratory gating in cardiac positron emission tomography

2020· article· en· W3003954236 on OpenAlexaff
Spencer Manwell, Ran Klein, Tong Xu, Robert A. deKemp

Bibliographic record

VenueMedical Physics · 2020
Typearticle
Languageen
FieldMedicine
TopicMedical Imaging Techniques and Applications
Canadian institutionsOttawa HospitalCarleton UniversityUniversity of Ottawa
Fundersnot available
KeywordsPositron emission tomographyGatingNuclear medicinePositron emissionCardiac PETTracking (education)MedicineFiducial markerRespiratory monitoringRespiratory systemAlgorithmComputer scienceBiomedical engineeringRadiologyInternal medicine

Abstract

fetched live from OpenAlex

PURPOSE: A data-driven motion tracking system was developed for respiratory gating in positron emission tomography (PET)/computed tomography (CT) studies. The positron emission tracking system (PeTrack) estimates the position of a low-activity fiducial marker placed on the patient during imaging. The aim of this study was to compare the performance of PeTrack against that of the real-time position management (RPM) system as applied to respiratory gating in cardiac PET/CT studies. METHODS: Rb myocardial perfusion studies were retrospectively processed with PeTrack to generate respiratory motion signals and triggers. Fifty acquisitions from the initial cohort, conducted under physiologic rest and stress, were considered for analysis. Respiratory-gated reconstructions were performed using reconstruction software provided by the vendor. The respiratory signals and triggers of the gating systems were compared using quantitative measurements of the respiratory signal correlation, median, and interquartiles range (IQR) of observed respiratory rates and the relative frequencies of respiratory cycle outliers. Quantitative measurements of left-ventricular wall thicknesses and motion due to respiration were also compared. Real-time position management signals were also retrospectively processed using the trigger detection method of PeTrack for a third comparator ("RPMretro") that allowed direct comparison of the motion tracking quality independently of differences in the trigger detection methods. The comparison of PeTrack to the original RPM data represent a practical comparison of the two systems, whereas that of PeTrack and RPMretro represents an equal comparison of the two. Nongated images were also reconstructed to provide reference left-ventricular wall thicknesses. LV wall thickness and motion measurements were repeated for a subset of cases with motion ≥7 mm as image artifacts were expected to be more severe in these cases. RESULTS: A significant correlation (P < 0.05) was observed between the RPM and PeTrack respiratory signals in 45/50 acquisitions; the mean correlation coefficient was 0.43. Similar results were found between PeTrack and RPMretro. No significant difference was observed between the RPM and PeTrack with respect to median respiratory rates and the percentage of respiratory cycles outliers. Respiratory rate variability (IQR) was significantly higher with PeTrack vs RPM (P = 0.002) and RPMretro (P = 0.04). Both PeTrack and RPM had a significant increase in the percentage of respiratory rate outliers compared to RPMretro (P < 0.001 and P = 0.001, respectively). All methods indicated significant differences in LV thickness compared to nongated images (P < 0.02). LV thickness was significantly larger for PeTrack compared to RPMretro in the highest motion subset (P = 0.009). Images gated with RPMretro showed significant increases in motion compared to both PeTrack (P < 0.001) and prospective RPM (P = 0.002). In the subset of highest motion cases, the difference between RPM and RPMretro was no longer present. CONCLUSIONS: Rb cardiac perfusion PET/CT studies. Real-time position management performance improved after retrospective processing and led to enhanced performance compared to both PeTrack and prospective RPM. With further development PeTrack has the potential to reduce the need for ancillary hardware systems to monitor respiratory motion.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.010
metaresearch head score (Gemma)0.023
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Non-randomized trial · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.010
Threshold uncertainty score0.056

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0100.023
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0020.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.032
GPT teacher head0.355
Teacher spread0.322 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNon-randomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2020
Admission routes1
Has abstractyes

Explore more