Excellent mid‐term osseointegration and implant survival using metaphyseal sleeves in revision total knee arthroplasty
Bibliographic record
Abstract
PURPOSE: Metaphyseal fixation in revision total knee arthroplasty (RTKA) is a very promising treatment option for extended bone defects. Currently published mid-term results remain limited. The purpose was to analyse the implant durability, the clinical and the radiological mid-term results in RTKA when using metaphyseal sleeves. METHODS: Clinical and radiological follow-up examinations were performed in 92 patients (93 knees) with RTKA using hybrid fixation technique (cementless sleeves and stem). Radiographic measurements regarding osseointegration at the bone-sleeve interface were performed and the range of motion (ROM), a subjective satisfaction score (SSS), the American Knee Society Score (KSS), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) as well as the SF-36 Health survey were examined. Bone defects were analysed using the Anderson Orthopaedic Research Institute (AORI) classification. RESULTS: No knee had to be revised due to aseptic loosening at the time of the follow-up (mean 6.3 years ± 2.3, minimum 2 years). Satisfactory radiographic osseointegration at the sleeve/bone interface was detected in 96.1% of cases. 17 knees (18.2%) had to be re-revised, 15 of them due to a recurrent infection and 2 due to aseptic reasons (mediolateral instability and a periprosthetic fracture). The median of the ROM (96°), SSS (8), KSS (87), WOMAC (9), SF-36 MCS (55) and SF-36 PCS (38) showed very satisfying results. CONCLUSION: No case of aseptic loosening was found in this large series of RTKA with extended bone defects using metaphyseal sleeve fixation. In this large retrospective series, it has been shown that this technique is an excellent treatment option for extended bone defects in RTKA surgery. LEVEL OF EVIDENCE: Retrospective cohort study, level III.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.002 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".