Investigation of transcutaneous electrical nerve stimulation improvements with microneedle array electrodes based on multiphysics simulation
Bibliographic record
Abstract
This paper investigates microneedle array electrodes for transcutaneous electrical nerve stimulation, and compares their performance with conventional surface electrodes. A three-dimensional model of tissue was developed for finite element multiphysics simulations. Investigations included current density in different depths of a tissue, space constant under electrodes, specific absorption ratio of tissue, selectivity of stimulation, temperature rise, and blood flow. Results showed that microneedle electrodes have up to 10% higher selectivity than the surface electrodes. Furthermore, it was found that stimulation using microneedle electrodes provides more robust current density at different tissue depths compared to the surface electrode stimulation. Microneedle electrodes showed enhanced stimulation parameters, particularly for targeting a specific nerve in a specific depth of a tissue.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".