MétaCan
Menu
Back to cohort
Record W3005881782 · doi:10.1016/j.bjane.2020.02.012

Management of a bi-caval dual lumen cannula clot obstruction after TEE guided diagnosis: a case report

2020· article· en· W3005881782 on OpenAlexaff
Raffael Pereira Cezar Zamper, Daniel Bainbridge, Dave Nagpal, Satoru Fujii

Bibliographic record

VenueBrazilian Journal of Anesthesiology (English Edition) · 2020
Typearticle
Languageen
FieldEngineering
TopicMechanical Circulatory Support Devices
Canadian institutionsLondon Health Sciences CentreWestern University
Fundersnot available
KeywordsCannulaMedicineLumen (anatomy)Clot formationSurgeryRadiologyInternal medicineCoagulation

Abstract

fetched live from OpenAlex

BACKGROUND: Veno-venous extracorporeal membrane oxygenation is an established therapy for patients with refractory acute respiratory distress syndrome (ARDS). One complication related to the use of veno-venous extracorporeal membrane oxygenation is thrombosis despite proper anticoagulation. We report the diagnosis and management of a clot-obstruction in a single site cannula placed through the internal jugular vein, guided by transesophageal echocardiography. CASE REPORT: A 39 year-old male developed acute respiratory distress syndrome and hemodynamic instability after an episode of pulmonary aspiration in the ICU. Eight hours after placement of a single site veno-venous extracorporeal membrane oxygenation, suddenly the perfusionist noticed a reduction in flow. TEE showed a thrombus-like mass obstructing the inflow port in SVC and inflow at IVC was intact. After unsuccessful attempts to reposition the cannula, the team decided to insert additional femoral inflow cannula through the IVC. The single site catheter was then pulled out until its tip was positioned in the right atrium and all three ports of the catheter were switched to the infusion ports. After this, flows and oxygenation improved significantly. Unfortunately, despite all of the efforts, the patient died 2 days later. DISCUSSION: The diagnosis of veno-venous extracorporeal membrane oxygenation cannula obstruction is based on reduced inflow rates, hemodynamic instability and poor oxygenation of blood. TEE allows evaluation of the flows inside the cannula and in this case, an obstruction was found. The management presented points to the fact that in a situation of catheter obstruction caused by a clot, there is a feasible alternative to assure minimal interruption of the hemodynamic support offered by the veno-venous extracorporeal membrane oxygenation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.006
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Case report · Consensus signal: Case report
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.011
Threshold uncertainty score0.010

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.006
Meta-epidemiology (narrow)0.0030.001
Meta-epidemiology (broad)0.0020.002
Bibliometrics0.0040.002
Science and technology studies0.0040.002
Scholarly communication0.0030.004
Open science0.0020.003
Research integrity0.0110.006
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.228
Teacher spread0.213 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designCase report
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueBrazilian Journal of Anesthesiology (English Edition)Same topicMechanical Circulatory Support DevicesFrench-language works237,207