MétaCan
Menu
Back to cohort
Record W3007910548 · doi:10.1109/tbme.2020.2975746

Analytical and Numerical Model of High Intensity Focused Ultrasound Enhanced With Nanoparticles

2020· article· en· W3007910548 on OpenAlexafffund
Moslem Sadeghi‐Goughari, Soo Jeon, Hyock‐Ju Kwon

Bibliographic record

VenueIEEE Transactions on Biomedical Engineering · 2020
Typearticle
Languageen
FieldEngineering
TopicUltrasound and Hyperthermia Applications
Canadian institutionsUniversity of Waterloo
FundersNatural Sciences and Engineering Research Council of CanadaGovernment of Ontario
KeywordsNanoparticleIntensity (physics)UltrasoundHigh-intensity focused ultrasoundMaterials scienceComputer scienceNanotechnologyMedicineOpticsPhysicsRadiology

Abstract

fetched live from OpenAlex

OBJECTIVE: High intensity focused ultrasound (HIFU) is a new noninvasive therapeutics that allows local treatment of solid tumors through a hyperthermal mechanism using ultrasonic energy. One promising strategy to increase the thermal efficiency of HIFU is to employ nanoparticles (NPs) as ultrasound agents for the hyperthermia procedure. However, the interaction mechanism between NPs and ultrasonic waves has not been well understood. METHODS: In an effort to investigate the heating process of NPs-enhanced HIFU, we derived a set of HIFU equations governing the temperature variation during the thermal ablation based on the principle of conservation of energy for heat transfer mechanism. A numerical model was developed to solve the HIFU equations to simulate the absorption mechanism of HIFU in the presence of NPs, the consequent heat transfer process, and the temperature rise profile during the sonication period. The accuracy of numerical model was verified by performing a series of experiments on tissue-mimicking phantoms embedded with magnetic NPs (MNPs). RESULTS: The transport processes taking place at the boundaries between NPs and surrounding medium played the major role in the temperature rise during HIFU sonication. Besides, the effects of MNPs on rising temperature were improved by amplifying the ultrasonic power and frequency as well as by increasing the MNP concentration. CONCLUSION: A quantitative comparison with experimental results demonstrated the potential of the numerical model to accurately predict the heating mechanism of HIFU mediated by NPs. SIGNIFICANCE: The proposed method can help with simulation of HIFU when NPs are employed as ultrasound agents.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.015
Threshold uncertainty score0.029

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0010.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0030.001
Insufficient payload (model declined to judge)0.0040.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.188
Teacher spread0.177 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations24
Published2020
Admission routes2
Has abstractyes

Explore more

Same venueIEEE Transactions on Biomedical EngineeringSame topicUltrasound and Hyperthermia ApplicationsFrench-language works237,207