A Contact-Free, Ballistocardiography-Based Monitoring System (Emfit QS) for Measuring Nocturnal Heart Rate and Heart Rate Variability: Validation Study

2020· article· en· W3010230791 on OpenAlexvenueno aff
Ville Vesterinen, Niina Rinkinen, Ari Nummela

Bibliographic record

VenueJMIR Biomedical Engineering · 2020
Typearticle
Languageen
FieldMedicine
TopicHeart Rate Variability and Autonomic Control
Canadian institutionsnot available
Fundersnot available
KeywordsHeart rate variabilityHeart rateNocturnalMedicineBallistocardiographyCardiologyMorningElectrocardiographyHolter monitorInternal medicinePhysical therapyBlood pressure

Abstract

fetched live from OpenAlex

Background Heart rate (HR) and heart rate variability (HRV) measurements are widely used to monitor stress and recovery status in sedentary people and athletes. However, effective HRV monitoring should occur on a daily basis because sparse measurements do not allow for a complete view of the stress-recovery balance. Morning electrocardiography (ECG) measurements with HR straps are time-consuming and arduous to perform every day, and thus compliance with regular measurements is poor. Contact-free, ballistocardiography (BCG)-based Emfit QS is effortless for daily monitoring. However, to the best of our knowledge, there is no study on the accuracy of nocturnal HR and HRV measured via BCG under real-life conditions. Objective The aim of this study was to evaluate the accuracy of Emfit QS in measuring nocturnal HR and HRV. Methods Healthy participants (n=20) completed nocturnal HR and HRV recordings at home using Emfit QS and an ECG-based reference device (Firstbeat BG2) during sleep. Emfit QS measures BCG by a ferroelectret sensor installed under a bed mattress. HR and the root mean square of successive differences between RR intervals (RMSSD) were determined for 3-minute epochs and the sleep period mean. Results A trivial mean bias was observed in the mean HR (mean –0.8 bpm [beats per minute], SD 2.3 bpm, P=.15) and Ln (natural logarithm) RMSSD (mean –0.05 ms, SD 0.25 ms, P=.33) between Emfit QS and ECG. In addition, very large correlations were found in the mean values of HR (r=0.90, P<.001) and Ln RMSSD (r=0.89, P<.001) between the devices. A greater amount of erroneous or missing data (P<.001) was observed in the Emfit QS measurements (28.3%, SD 14.4%) compared with the reference device (1.1%, SD 2.3%). The results showed that 5.0% of the mean HR and Ln RMSSD values were outside the limits of agreement. Conclusions Based on the present results, Emfit QS provides nocturnal HR and HRV data with an acceptable, small mean bias when calculating the mean of the sleep period. Thus, Emfit QS has the potential to be used for the long-term monitoring of nocturnal HR and HRV. However, further research is needed to assess reliability in HR and HRV detection.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.006
metaresearch head score (Gemma)0.006
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.006
Threshold uncertainty score0.031

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0060.006
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.024
GPT teacher head0.257
Teacher spread0.233 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations20
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueJMIR Biomedical EngineeringSame topicHeart Rate Variability and Autonomic ControlFrench-language works237,207