MétaCan
Menu
Back to cohort
Record W3010230791 · doi:10.2196/16620

A Contact-Free, Ballistocardiography-Based Monitoring System (Emfit QS) for Measuring Nocturnal Heart Rate and Heart Rate Variability: Validation Study

2020· article· en· W3010230791 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

venuePublished in a venue whose home country is Canada.
no affNo Canadian affiliation: this work is invisible to an affiliation-only frame.
No Canadian affiliation. An affiliation-only frame, the usual design, would never have seen this work. It is one of the works that make the case for inverting the frame.

Bibliographic record

VenueJMIR Biomedical Engineering · 2020
Typearticle
Languageen
FieldMedicine
TopicHeart Rate Variability and Autonomic Control
Canadian institutionsnot available
Fundersnot available
KeywordsHeart rate variabilityHeart rateNocturnalMedicineBallistocardiographyCardiologyMorningElectrocardiographyHolter monitorInternal medicinePhysical therapyBlood pressure

Abstract

fetched live from OpenAlex

Background Heart rate (HR) and heart rate variability (HRV) measurements are widely used to monitor stress and recovery status in sedentary people and athletes. However, effective HRV monitoring should occur on a daily basis because sparse measurements do not allow for a complete view of the stress-recovery balance. Morning electrocardiography (ECG) measurements with HR straps are time-consuming and arduous to perform every day, and thus compliance with regular measurements is poor. Contact-free, ballistocardiography (BCG)-based Emfit QS is effortless for daily monitoring. However, to the best of our knowledge, there is no study on the accuracy of nocturnal HR and HRV measured via BCG under real-life conditions. Objective The aim of this study was to evaluate the accuracy of Emfit QS in measuring nocturnal HR and HRV. Methods Healthy participants (n=20) completed nocturnal HR and HRV recordings at home using Emfit QS and an ECG-based reference device (Firstbeat BG2) during sleep. Emfit QS measures BCG by a ferroelectret sensor installed under a bed mattress. HR and the root mean square of successive differences between RR intervals (RMSSD) were determined for 3-minute epochs and the sleep period mean. Results A trivial mean bias was observed in the mean HR (mean –0.8 bpm [beats per minute], SD 2.3 bpm, P=.15) and Ln (natural logarithm) RMSSD (mean –0.05 ms, SD 0.25 ms, P=.33) between Emfit QS and ECG. In addition, very large correlations were found in the mean values of HR (r=0.90, P<.001) and Ln RMSSD (r=0.89, P<.001) between the devices. A greater amount of erroneous or missing data (P<.001) was observed in the Emfit QS measurements (28.3%, SD 14.4%) compared with the reference device (1.1%, SD 2.3%). The results showed that 5.0% of the mean HR and Ln RMSSD values were outside the limits of agreement. Conclusions Based on the present results, Emfit QS provides nocturnal HR and HRV data with an acceptable, small mean bias when calculating the mean of the sleep period. Thus, Emfit QS has the potential to be used for the long-term monitoring of nocturnal HR and HRV. However, further research is needed to assess reliability in HR and HRV detection.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.941
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0030.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.024
GPT teacher head0.257
Teacher spread0.233 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it