MétaCan
Menu
Back to cohort
Record W3010333783 · doi:10.3390/en13051150

Experimentally Measured Thermal Masses of Adsorption Heat Exchangers

2020· article· en· W3010333783 on OpenAlexafffund
Kyle Gluesenkamp, Andrea Frazzica, Andreas Velte, S.J. Metcalf, Zhiyao Yang, Mina Rouhani, Corey Blackman, Ming Qu, Eric Laurenz, Angeles M. Rivero Pacho, Samuel Hinmers, R.E. Critoph, Majid Bahrami, Gerrit Füldner, Ingemar Hallin

Bibliographic record

VenueEnergies · 2020
Typearticle
Languageen
FieldEngineering
TopicAdsorption and Cooling Systems
Canadian institutionsSimon Fraser University
FundersEngineering and Physical Sciences Research CouncilNatural Sciences and Engineering Research Council of CanadaBundesministerium für Bildung und ForschungUT-BattelleBundesministerium für Wirtschaft und EnergieBattelleU.S. Department of Energy
KeywordsThermalWork (physics)Heat exchangerThermal massAdsorptionHeat transferThermodynamicsMass transferNuclear engineeringMaterials scienceMechanical engineeringProcess engineeringChemistryEngineeringPhysicsOrganic chemistry

Abstract

fetched live from OpenAlex

The thermal masses of components influence the performance of many adsorption heat pump systems. However, typically when experimental adsorption systems are reported, data on thermal mass are missing or incomplete. This work provides original measurements of the thermal masses for experimental sorption heat exchanger hardware. Much of this hardware was previously reported in the literature, but without detailed thermal mass data. The data reported in this work are the first values reported in the literature to thoroughly account for all thermal masses, including heat transfer fluid. The impact of thermal mass on system performance is also discussed, with detailed calculation left for future work. The degree to which heat transfer fluid contributes to overall effective thermal mass is also discussed, with detailed calculation left for future work. This work provides a framework for future reporting of experimental thermal masses. The utilization of this framework will enrich the data available for model validation and provide a more thorough accounting of adsorption heat pumps.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.006
Threshold uncertainty score0.021

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.004
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0010.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0060.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.023
GPT teacher head0.208
Teacher spread0.185 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations36
Published2020
Admission routes2
Has abstractyes

Explore more

Same venueEnergiesSame topicAdsorption and Cooling SystemsFrench-language works237,207