MétaCan
Menu
Back to cohort
Record W3010383368 · doi:10.1002/ccd.28832

Single‐center prospective study examining use of the Wattson temporary pacing guidewire for transcatheter aortic valve replacement

2020· article· en· W3010383368 on OpenAlexaff
Mark Hensey, Janarthanan Sathananthan, Abdullah Alkhodair, Uri Landes, David Wood, David Daniels, John G. Webb

Bibliographic record

VenueCatheterization and Cardiovascular Interventions · 2020
Typearticle
Languageen
FieldMedicine
TopicCardiac Valve Diseases and Treatments
Canadian institutionsSt. Paul's HospitalUniversity of British Columbia
Fundersnot available
KeywordsMedicineConcomitantValve replacementSingle CenterSurgeryClinical endpointTransvenous pacingCatheterBalloonProspective cohort studyTamponadeCardiologyRandomized controlled trialStenosis

Abstract

fetched live from OpenAlex

OBJECTIVES: To assess the safety and efficacy of the Wattson temporary pacing guidewire. BACKGROUND: Transcatheter aortic valve replacement (TAVR) requires a guidewire for device delivery and generally requires temporary pacing wire for burst and back-up pacing. The Wattson wire provides concomitant support and bipolar pacing without the need to place a temporary venous pacemaker (TVP). METHODS: This was a single-center nonrandomized prospective clinical trial enrolling 20 patients. The primary endpoint was defined as successful rapid pacing and transcatheter heart valve (THV) delivery with no loss of capture. Safety, qualitative and quantitative secondary outcomes were also analyzed. RESULTS: Mean age was 77.4 ± 9.0 years. Mean Society of Thoracic Surgery (STS) score was 3.0 ± 1.5%. All patients received a balloon-expandable valve via a transfemoral approach. All patients met the primary end-point. One patient (5%) had balloon predilatation and six patients (30%) had postdilatation, all using the wire. Mean pacing threshold was 2.2 ± 1.2 mA that was evaluated prior to placing an insulating catheter over the wire. One patient required TVP placement and subsequent permanent pacemaker implantation due to complete heart block post THV deployment. There were no incidences of cardiac perforation or tamponade. One patient required valve reintervention, which was not related to the device. CONCLUSIONS: The Wattson wire offered predictable guidewire support with concomitant reliable bipolar pacing at low thresholds to allow safe THV delivery in this patient cohort. It has the potential to make TAVR a safer and more efficient procedure.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.005
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.012

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.005
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0000.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.090
GPT teacher head0.328
Teacher spread0.238 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations10
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueCatheterization and Cardiovascular InterventionsSame topicCardiac Valve Diseases and TreatmentsFrench-language works237,207