MétaCan
Menu
← Back to cohort
Record W3011670721 · doi:10.1088/1361-6560/ab7eef

Technical note: development and validation of a Monte Carlo tool for analysis of patient-generated photon scatter

2020· article· en· W3011670721 on OpenAlexafffund
Kaiming Guo, Harry Ingleby, Idris A. Elbakri, Timothy Van Beek, Boyd McCurdy

Bibliographic record

VenuePhysics in Medicine and Biology · 2020
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsUniversity of ManitobaCancerCare Manitoba
FundersNatural Sciences and Engineering Research Council of CanadaCancerCare Manitoba Foundation
KeywordsMonte Carlo methodPhotonPhysicsFluenceImaging phantomOpticsComputational physicsBeam (structure)BremsstrahlungCompton scatteringComputer scienceStatisticsMathematicsLaser

Abstract

fetched live from OpenAlex

Abstract Scattered radiation unavoidably generated in the patient will negatively impact both kilovoltage (KV) and megavoltage (MV) imaging applications. Recently, ‘hybrid’ methods (i.e. combining analytical and Monte Carlo (MC) techniques) are being investigated as a solution to accurately yet quickly calculate the scattered contribution for both KV and MV images. We have developed a customized MC simulation user code for investigating the individual components of patient-scattered photon fluence, which serves as a valuable tool in this area of research. The MC tool is based on the EGSnrc/DOSXYZnrc user code. The IAUSFL flag options associated with subroutine AUSGAB, combined with LATCH tracking, are used to classify the various interactions of particles with the media. Photons are grouped into six different categories: primary, 1st Compton scatter, 1st Rayleigh scatter, multiple scatter, bremsstrahlung, and positron annihilation. We take advantage of the geometric boundary check in DOSXYZnrc, to write exiting photon particle information to a phase-space file. The tool is validated using homogeneous and heterogeneous phantom configurations with monoenergetic and polyenergetic beams under parallel and divergent beam geometry, comparing MC-simulated exit primary fluence and singly-scattered fluence to corresponding analytical calculations. This MC tool has been validated to separately score the primary and scatter fluence components of the KV and MV imaging applications in the field of radiation therapy. The results are acceptable for the various configurations and beam energies tested here. Overall, the mean percentage differences are less than 0.2% and standard deviations less than 1.6%. This will be a critical test instrument for research in photon scatter applications and particularly for the development of hybrid methods, and is freely available from the authors for research purposes. 5

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.010
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.009
Threshold uncertainty score0.031

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.010
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0020.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0090.003

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.077
GPT teacher head0.364
Teacher spread0.287 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2020
Admission routes2
Has abstractyes

Explore more

Same venuePhysics in Medicine and Biology→Same topicAdvanced Radiotherapy Techniques→French-language works237,207→