MétaCan
Menu
Back to cohort

Are Automated Office Blood Pressure Readings More Variable Than Home Readings?

2020· article· en· W3012654729 on OpenAlexafffund
Martin G. Myers, Janusz Kaczorowski

Bibliographic record

VenueHypertension · 2020
Typearticle
Languageen
FieldMedicine
TopicBlood Pressure and Hypertension Studies
Canadian institutionsCanadian Institutes of Health ResearchHealth Sciences CentreUniversity of TorontoSunnybrook Health Science Centre
FundersCanadian Institutes of Health Research
KeywordsMedicineBlood pressureAmbulatory blood pressureAmbulatoryCardiologyGold standard (test)Internal medicineSignificant differenceMean differenceConfidence interval

Abstract

fetched live from OpenAlex

A recent report from the American Heart Association stated that automated office blood pressure (AOBP) is preferred for evaluating office blood pressure (BP) because it is more accurate and devoid of white coat effect, which is mostly caused by higher systolic BP readings. However, AOBP has been criticized for being too variable to be used for identifying patients with possible hypertension. We, therefore, compared AOBP with home BP monitoring (HBPM) with respect to variability as determined by their relationship with the gold standard for determining BP status, awake ambulatory BP (ABP). The main focus was on systolic BP. Data on AOBP, HBPM, and awake ABP were collected on 300 patients referred from the community for 24-hour ambulatory BP monitoring. The SD of the difference between mean systolic awake ABP (136.4±11.5) and AOBP (131.2±15.7) was 13.6 mm Hg compared with 13.1 for the SD of the difference ( P =0.52) between the systolic awake ABP and the HBPM (136.7±16.1). Coefficients of correlation were slightly lower for systolic awake ABP versus AOBP ( r =0.54) compared with HBPM ( r =0.60). Coefficients of variation for AOBP (12.0%) and HBPM (11.8%) and variances between AOBP and HBPM were similar. Of the 139 patients with hypertension as defined by a manual office systolic BP ≥140 mm Hg, variability in BP readings as determined by the SDs of the mean difference versus awake ABP were similar ( P =0.56) for AOBP (14.6) and HBPM (13.9). Overall, both systolic AOBP and HBPM exhibited a similar degree of variability as assessed by the various methods.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: Not applicable
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.209
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.039
GPT teacher head0.250
Teacher spread0.212 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designNot applicable
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations12
Published2020
Admission routes2
Has abstractyes

Explore more

Same venueHypertensionSame topicBlood Pressure and Hypertension StudiesFrench-language works237,207