MétaCan
Menu
Back to cohort
Record W3015349041 · doi:10.1088/2057-1976/ab8741

Time-course study of a gold nanoparticle contrast agent for cardiac-gated micro-CT imaging in mice

2020· article· en· W3015349041 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.

Bibliographic record

VenueBiomedical Physics & Engineering Express · 2020
Typearticle
Languageen
FieldEngineering
TopicAdvanced X-ray and CT Imaging
Canadian institutionsUniversity of British Columbia
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsContrast (vision)Colloidal goldNanoparticleBiomedical engineeringMaterials scienceNanotechnologyMedicineComputer scienceArtificial intelligence

Abstract

fetched live from OpenAlex

Although micro-computed tomography (micro-CT) images have high contrast for bone or air, between soft tissues the contrast is typically low. To overcome this inherent issue, attenuating exogenous contrast agents are used to provide contrast enhancement in the vasculature and abdominal organs. The aim of this study is to measure the contrast enhancement time course for a gold nanoparticle blood-pool contrast agent and use it to perform cardiac-gated 4D micro-CT scans of the heart. Six healthy female C57BL/6 mice were anesthetized and imaged after receiving an injected dose of MVivo gold nanoparticle blood-pool contrast agent. Following the injection, we performed micro-CT scans at 0, 0.25, 0.5, 0.75, 1, 2, 4, 8, 24, 48 and 72 h. The mean CT number was measured for 7 different organs. No contrast enhancement was noticed in the bladder, kidneys or muscle during the time-course study. However, it clearly appears that the contrast enhancement is high in both right ventricle and vena cava. To perform cardiac-gated imaging, either the gold nanoparticle agent (n = 3) or an iodine-based (n = 3) contrast agent was introduced and images representing 9 phases of the cardiac cycle were obtained in 6 additional mice. A few typical cardiac parameters were measured or calculated, with similar accuracy between the gold and iodinated agents, but better visualization of structures with the gold agent. The MVivo Au contrast agent can be used for investigations of cardiac or vascular disease with a single bolus injection, with an optimal cardiac imaging window identified during the first hour after injection, demonstrating similar image quality to iodinated contrast agents and excellent measurement accuracy. Furthermore, the long-lasting contrast enhancement of up to 8 h can be very useful for scanning protocols that require longer acquisition times.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.730
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.220
Teacher spread0.213 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it