MétaCan
Menu
Back to cohort
Record W3016042458 · doi:10.1115/1.4046862

Dynamic Left Atrioventricular Phantom Test Bed Emulating Mitral Valve Motion

2020· article· en· W3016042458 on OpenAlexaff
Toufic Azar, Stewart McLennan, Michael T. Walsh, Jorge Angeles, József Kövecses, Tabitha Jaramillo, Rosaire Mongrain, Renzo Cecere

Bibliographic record

VenueJournal of Medical Devices · 2020
Typearticle
Languageen
FieldMedicine
TopicCardiac Valve Diseases and Treatments
Canadian institutionsRoyal Victoria HospitalMcGill University Health CentreRoyal Victoria Regional Health CentreMcGill University
Fundersnot available
KeywordsImaging phantomBiomedical engineeringAnnulus (botany)Pulsatile flowMaterials scienceHeart valveImplantSimulationComputer scienceMechanical engineeringEngineeringMedicineSurgeryComposite materialCardiologyNuclear medicine

Abstract

fetched live from OpenAlex

Abstract Novel catheter-based medical procedures targeting heart valve structures are currently under development. These techniques entail installing a prosthetic implant on valves inside a beating heart. The development of these approaches requires a simple and effective validation test bed. Current early process testing methods rely on both static and dynamically pressurized excised porcine hearts. The variability between excised-tissue mechanical properties poses problems of reproducibility. In addition, these test beds do not emulate annulus motion, which affects the implant installation. A reproducible phantom of the left atrioventricular chambers was developed. The system consists of a hydraulic constant flow arrangement and a polyvinyl alcohol phantom heart with material properties that mimic passive myocardium mechanical properties and annulus motion. The system was then used to emulate blood flow through an actual heart. The building process starts by obtaining an accurate computer-aided design (CAD) model of a human heart, from which, a mold is produced using a novel rapid-freezing prototyping method and computer numerical control machining. The phantom is then cast-out of polyvinyl alcohol (PVA), a hydrogel, whose mechanical properties are set by subjecting the phantom to freeze and thaw cycles. Subsequently, blood flow is emulated at a constant volumetric rate at the atrial pressure observed in a healthy adult human heart at rest. The annulus motion is implemented by suturing the outside of the phantom to a one-degree-of-freedom cam-follower mechanism reproducing valve motion. Such test beds could play a significant role in future development of medical devices.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.031
Threshold uncertainty score0.521

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.002
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.342
Teacher spread0.328 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Medical DevicesSame topicCardiac Valve Diseases and TreatmentsFrench-language works237,207