MétaCan
Menu
Back to cohort
Record W3016911510 · doi:10.1139/cjc-2020-0113

Linear energy transfer dependence of transient yields in water irradiated by 150 keV – 500 MeV protons in the limit of low dose rates

2020· article· en· W3016911510 on OpenAlexafffundvenue
Ahmed Alanazi, Jintana Meesungnoen, Jean‐Paul Jay‐Gerin

Bibliographic record

VenueCanadian Journal of Chemistry · 2020
Typearticle
Languageen
FieldMedicine
TopicRadiation Therapy and Dosimetry
Canadian institutionsUniversité de Sherbrooke
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsLinear energy transferChemistryProtonIrradiationRadiolysisIonizing radiationContext (archaeology)IonRange (aeronautics)Atomic physicsMonte Carlo methodRadiochemistryElectronNuclear physicsPhysicsMaterials science

Abstract

fetched live from OpenAlex

FLASH radiotherapy is a new irradiation method in which large doses of ionizing radiation are delivered to tumors almost instantly (a few milliseconds), paradoxically sparing healthy tissue while preserving anti-tumor activity. Although this technique is primarily studied in the context of electron and photon therapies, proton delivery at high dose rates can also reduce the adverse side effects on normal cells. So far, no definitive mechanism has been proposed to explain the differences in the responses to radiation between tumor and normal tissues. Given that living cells and tissues consist mainly of water, we set out to study the effects of high dose rates on the radiolysis of water by protons in the energy range of 150 keV – 500 MeV (i.e., for linear energy transfer (LET) values between ∼72.2 and 0.23 keV/μm, respectively) using Monte Carlo simulations. To validate our methodology, however, we, first, report here the results of our calculations of the yields (G values) of the radiolytically produced species, namely the hydrated electron ([Formula: see text]), • OH, H • , H 2 , and H 2 O 2 , for low dose rates. Overall, our simulations agree very well with the experiment. In the presence of oxygen, [Formula: see text] and H • atoms are rapidly converted into superoxide anion or hydroperoxyl radicals, with a well-defined maximum of [Formula: see text] at ∼1 μs. This maximum decreases substantially when going from low-LET 500 MeV to high-LET 150 keV irradiating protons. Differences in the geometry of the proton track structure with increasing LET readily explain this diminution in [Formula: see text] radicals.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.011
Threshold uncertainty score0.414

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.226
Teacher spread0.213 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2020
Admission routes3
Has abstractyes

Explore more

Same venueCanadian Journal of ChemistrySame topicRadiation Therapy and DosimetryFrench-language works237,207