MétaCan
Menu
Back to cohort
Record W3017230297 · doi:10.1016/j.adro.2020.04.007

A Rapid Transition to Voluntary Breath Hold From Device-Assisted Moderate Deep Inspiration Breath Hold for Patients Receiving Breast Radiation Therapy During the Coronavirus 2019 Pandemic

2020· article· en· W3017230297 on OpenAlexaff
Erin Barnett, D Comsa, Beibei Zhang, Tyler Pestill, Cari Bradley, Leslie Proctor, Gulaid Mohamoud, Michael P. Ryan, J. D. Loudon, Louis Fenkell

Bibliographic record

VenueAdvances in Radiation Oncology · 2020
Typearticle
Languageen
FieldMedicine
TopicEffects of Radiation Exposure
Canadian institutionsPrincess Margaret Cancer CentreUniversity of TorontoSouthlake Regional Health Center
Fundersnot available
KeywordsMedicineRadiation oncologyPandemicCoronavirus disease 2019 (COVID-19)Radiation therapyBreast cancerSevere acute respiratory syndrome coronavirus 2 (SARS-CoV-2)Intensive care medicineMedical physics2019-20 coronavirus outbreakOncologyEmergency medicineInternal medicineCancerInfectious disease (medical specialty)Pathology

Abstract

fetched live from OpenAlex

Preventing infection of radiation oncology patients during the coronavirus 2019 (COVID-19) pandemic is a priority in the radiation oncology community. The highly infectious nature and severity of COVID-19 requires a critical review of practices in our radiation medicine program. The worldwide radiation oncology community has described site-specific recommendations for supporting radiation oncology patients in the setting of a global pandemic. This consensus document recommends for breast cancer radiation therapy “avoiding use of active breathing control for radiotherapy due to the risk of aerosol contamination and minimization of devices requiring decontamination.”1Simcock R, Thomas TV, Mercy CE, et al. COVID-19: Global radiation oncology’s targeted response for pandemic preparedness. Clin Translat Radiat Oncol. https://doi.org/10.1016/j.ctro.2020.03.009Google Scholar The radiation medicine program at our facility treats approximately 1300 patients per year on 4 Elekta Agility (Elekta, Sweden) linear accelerators. Breast radiation therapy makes up more than 30% of our cases. The Active Breathing Coordinator (ABC) Response v3.0 system (Elekta) facilitates moderate deep inspiration breath hold (mDIBH) for cardiac sparing breast radiation therapy. The ABC system has been used at our institution for the majority of left breast radiation therapy treatments since 2013 to reduce the radiation dose to heart. The system is fully integrated with the linear accelerator and permits gated radiation therapy delivery. Patients breathe through a snorkel into the ABC system and the system controls the volume of air in the lungs and the duration of the breath hold. Based on the recommendation to avoid use of active breathing control for breast radiation therapy in the recent publication entitled “COVID-19: Global Radiation Oncology’s Targeted Response for Pandemic Preparedness,”1Simcock R, Thomas TV, Mercy CE, et al. COVID-19: Global radiation oncology’s targeted response for pandemic preparedness. Clin Translat Radiat Oncol. https://doi.org/10.1016/j.ctro.2020.03.009Google Scholar the medical physics and radiation therapy teams were tasked with transitioning patients receiving breast radiation therapy from mDIBH using the ABC system to a visually monitored voluntary breath hold (vBH) technique within a very short time frame. According to our target implementation timeline of 1.5 weeks, 3 groups of patients with breast cancer were identified that would be affected by this change:1.Patients simulated with mDIBH and currently on treatment using the ABC device. This group is subdivided into 2 subgroups:a.Patients completing treatment before the go-live dateb.Patients transitioning to vBH treatment technique2.Patients computed tomography (CT) simulated with ABC but not started on treatment3.Patients scheduled for CT simulation with ABC Patient numbers are summarized in Table 1. The implementation team’s first priority was to transition treatment to vBH and the second priority was to modify the CT simulation process to vBH. In anticipation of the growing effect of COVID-19 on the health care system, the oncology program was required to reduce the number of patient visits to the cancer center and the decision was made to not resimulate or replan these cases. The transition from mDIBH ABC treatment to a vBH treatment without resimulating the first group of patients is described. The second group of patients will be simulated and treated using a vBH technique.Table 1Patient groups using ABC and corresponding effect on radiation therapy treatmentPatient groupNo. of patientsAction1(a)On treatment with ABC mDIBH, with less than 5 fx remaining8Continue ABC mDIBH treatment1(b)On treatment with ABC mDIBH, with more than 5 fx remaining13Transition treatment to vBH2Scanned and planned using ABC mDIBH11Start treatment with vBHAbbreviations: ABC = Active Breathing Coordinator; fx = fractions; mDIBH = moderate deep inspiration breath hold; vBH = voluntary breath hold. Open table in a new tab Abbreviations: ABC = Active Breathing Coordinator; fx = fractions; mDIBH = moderate deep inspiration breath hold; vBH = voluntary breath hold. In our implementation in place of the ABC system controlling the volume of air held, vBH is based on monitoring skin marks using the closed-circuit television (CCTV) system present on all linear accelerators, as described elsewhere.2Conroy L. Yeung R. Watt E. et al.Evaluation of target and cardiac position during visually monitored deep inspiration breath-hold for breast radiotherapy.J Appl Clin Med Phys. 2016; 17: 25-36Crossref PubMed Scopus (21) Google Scholar,3Bartlett F.R. Colgan R.M. Carr K. et al.The UK HeartSpare Study: Randomised evaluation of voluntary deep-inspiratory breath-hold in women undergoing breast radiotherapy.Radiother Oncol. 2013; 108: 242-247Abstract Full Text Full Text PDF PubMed Scopus (154) Google Scholar Aside from the difference in breath hold techniques and the requirement to manually gate the linear accelerator, the radiation therapy delivery process remained largely unchanged. Skin marks were placed on the patient’s left side in a location that was visible using the CCTV system. Skin marks consisted of 3 parallel lines separated by 5 mm. Patients were coached into vBH while the marks on the skin were monitored relative to the coronal laser. When the skin marks align with the coronal laser, the beam is turned on. Skin marks are shown in Figure 1 for a patient while free breathing (Fig 1a) and while in breath hold (Fig 1b). A countdown timer was used to monitor the breath hold duration. In addition to monitoring skin marks relative to the coronal laser, megavoltage (MV) electronic portal daily imaging was performed. Also, during delivery of beams, MV cine images were acquired to monitor internal anatomy and to assess reproducibility of patient anatomy during an individual breath hold and from breath hold to breath hold. A practical aspect of this implementation is that for some of our treatment plans the lateral gantry angle blocked the coronal laser at the axial level of midbreast. For these cases an additional set of skin marks was made more inferiorly to permit monitoring of patient position during vBH. Process maps describing the vBH treatment techniques were developed, tested, and revised for the following breast treatment: tangents, mono-isocentric 4 field, bilateral, and conformal boost. Figure 2 illustrates the timeline for the implementation of vBH for breast radiation therapy from the decision to transition to the go-live date. During this brief period of transition from ABC to vBH, a number of scheduled ABC CT simulations were delayed until a vBH simulation protocol was developed and implemented, as the advantage of offering a cardiac sparing treatment technique was believed to outweigh the effect of a short delay in starting radiation therapy for this patient group. The CT simulation team of radiation therapists was tasked to transition the ABC simulation process to a vBH technique. New CT scanning protocols were developed and reviewed by the committee that oversees the external beam program protocols and processes at our center. Patients able to hold their breath for a minimum of 18 s were considered eligible for vBH treatment. This minimum breath hold requirement is consistent with the previous requirement using the ABC device and was established to facilitate efficient delivery. Patients were also required to understand the breathing instructions to be eligible for vBH. If both of these eligibility criteria were met, then patients were coached on how to breathe (through mouth or nose according to patient comfort and with relaxed shoulders and back). vBH reproducibility was assessed by monitoring the marks on patients’ skin relative to the coronal laser before CT acquisition. Relevant information from the vBH training at the time of simulation was transcribed to the patient treatment setup note and included maximum breath hold duration, tattoo table heights for free breathing, and vBH. To prepare patients for the transition from the mDIBH to the vBH delivery technique, the treating radiation oncologist contacted each affected patient by phone in advance of the go-live date. Radiation oncologists explained the reason for this change in breath hold technique. Upon arrival at the treatment unit for the first vBH fraction, patients received a brief education session from the radiation therapists. Treating radiation therapists were able to gauge patient comfort with the vBH technique and provide additional breath hold coaching as needed. Staff education sessions for radiation therapy team members were coordinated on a treatment unit using a staff volunteer patient to simulate the process. vBH was implemented on a single linear accelerator initially to maintain a consistent treatment team. As more staff gained experience with the vBH technique, vBH treatment was offered on a second linear accelerator. Implementation of vBH required the treating therapists to enter the treatment room extra times compared with the mDIBH treatment technique. For tangent and 4 field deliveries, 2 extra trips into the room were required, once to make marks on skin and a second time to adjust MV panel position to capture the MV images. For boost deliveries, radiation therapists needed to make a single extra trip into the room to mark the patient’s skin. To accommodate the additional entries into the treatment room and skin marking steps, appointment times were increased by 10 minutes for tangent and 4 field treatments for the first fraction and increased by 5 minutes for subsequent fractions. Boost appointment times were increased by 5 minutes. It is anticipated that the appointment times will be returned to their original duration once the technique is fully established. To support this practice change, some additional machine configuration changes were required. The in-room lasers were configured to remain on for the duration of a typical breast treatment. Preset positions of the CCTV cameras were saved on each unit to best view the skin marks relative to the coronal laser. The inherent differences between the ABC and the vBH techniques is acknowledged. The most significant challenge is anticipated for the patients simulated using the ABC system but receiving treatment using the vBH technique. For this reason, skin marks included 3 parallel lines: the central line to be aligned with the coronal laser while in breath hold, a line 5 mm anterior to the central line, and a line 5 mm posterior to the central line. This generous skin mark threshold was included in the process to accommodate any patients whose breath hold with the vBH technique differed greatly from the ABC technique. The ABC system is configured for each patient to hold their breath at 80% of the maximum inhalation volume. For some patients being coached into a voluntary breath hold, it may be difficult to appreciate the 80% maximum inhalation threshold. The tendency for some patients was to overshoot the displacement between the free breathing and breath hold tattoo table height. Additional coaching was required such that patients were able to better match the breath hold achieved at CT simulation. The ±5-mm skin mark thresholds were found to be unnecessary, as patients were able to execute the vBH technique reproducibly. Challenges of this nature are not anticipated for patients who were CT simulated and treated in a vBH state. At the time of writing, 7 patients have been CT simulated using the vBH technique and 80 vBH fractions have been delivered. Radiation therapy team members report a smooth roll out of this rapid technique transition. No patients who have been simulated using the vBH technique have initiated treatment yet. Quality care in the context of breast cancer radiation therapy means continuing to offer cardiac sparing treatment techniques during the COVID-19 pandemic. Our radiation medicine program was able to respond quickly and efficiently to the recommendations from the global radiation oncology community and transition breast radiation therapy using the ABC system to a deviceless vBH technique. In total the transition took 7 clinical days of considerable effort, with team members from radiation oncology, radiation therapy, and medical physics working cohesively. On the eighth day all patients with breast cancer previously on treatment using the ABC device were transitioned to the vBH delivery technique and CT simulation for eligible patients was performed with the vBH technique.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.717
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.311
Teacher spread0.290 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueAdvances in Radiation OncologySame topicEffects of Radiation ExposureFrench-language works237,207