MétaCan
Menu
Back to cohort
Record W3018362391 · doi:10.1016/j.cjco.2020.04.008

Rate, Time Course, and Predictors of Implantable Cardioverter Defibrillator Infections: An Analysis From the SIMPLE Trial

2020· article· en· W3018362391 on OpenAlexaff
François Philippon, Gilles O’Hara, Jean Champagne, Stefan H. Hohnloser, Michael Glikson, Jörg Neuzner, Philippe Mabo, Xavier Viñolas, Josef Kautzner, Fredrik Gadler, Noa Lashevsky, Stuart J. Connolly, Yan Liu, Jeff S. Healey

Bibliographic record

VenueCJC Open · 2020
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsMcMaster UniversityPopulation Health Research InstituteUniversité LavalInstitut universitaire de cardiologie et de pneumologie de Québec
FundersBoston Scientific Corporation
KeywordsMedicineImplantable cardioverter-defibrillatorRandomized controlled trialComplicationUnivariate analysisSurgeryHematomaImplantInternal medicineMultivariate analysis

Abstract

fetched live from OpenAlex

Background The number of implantable cardioverter defibrillator (ICD) infections is increasing due to an increased number of ICD implants, higher-risk patients, and more frequent replacement procedures, which carry a higher risk of infection. Reducing the morbidity, mortality, and cost of ICD-related infections requires an understanding of the current rate of this complication and its predictors. Methods The S hock Impl ant E valuation Trial (SIMPLE) trial randomized 2500 ICD recipients to defibrillation testing or not. Over an average of 3.1 years, patients were seen every 6 months and examined for evidence of ICD infection, which was defined as requiring device removal and/or intravenous antibiotics. Results Within 24 months, 21 patients (0.8%) developed infection. Fourteen patients (67%) with infection presented within 30 days, 20 patients by 12 months, and only 1 patient beyond 12 months. Univariate analysis demonstrated that patients with primary electrical disorders (3 patients, P = 0.009) and those with a secondary prevention indication (13 patients, P = 0.0009) were more likely to develop infection. Among the 2.2% of patients who developed an ICD wound hematoma, 10.4% developed an infection. Among the 8.3% of patients requiring an ICD reintervention, 1.9% developed an infection. Conclusions This cohort of ICD recipients at high-volume centres have a low risk of device-related infection. However; strategies to reduce wound hematoma and the need for ICD reintervention could further reduce the rate of infection.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.010
metaresearch head score (Gemma)0.015
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.010
Threshold uncertainty score0.050

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0100.015
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0030.005
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0040.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.026
GPT teacher head0.306
Teacher spread0.280 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueCJC OpenSame topicCardiac pacing and defibrillation studiesFrench-language works237,207