MétaCan
Menu
Back to cohort
Record W3020134089 · doi:10.3934/bioeng.2020008

Skin dose enhancement from the application of skin-care creams using FF and FFF photon beams in radiotherapy: A Monte Carlo phantom evaluation

2020· article· en· W3020134089 on OpenAlexaff
Megha Sharma, James C. L. Chow

Bibliographic record

VenueAIMS bioengineering · 2020
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsUniversity of TorontoPrincess Margaret Cancer CentreUniversity Health NetworkToronto Metropolitan University
Fundersnot available
KeywordsImaging phantomMonte Carlo methodMaterials scienceBeam (structure)SiliconPhotonNuclear medicineOpticsMedicineOptoelectronicsPhysicsMathematics

Abstract

fetched live from OpenAlex

Skin-care cream is commonly applied to relieve skin redness in radiotherapy. However, using cream on the patient under the photon field would increase the skin dose in delivery. The aim of this study is to evaluate the dependences of skin dose enhancement on different beam and cream variables using Monte Carlo simulation. Using a solid water phantom with water-equivalent bolus, PMMA layer and cream layer, we irradiated it by 6 MV photon beams. Skin doses were calculated by varying the beam quality (flattening-filter (FF) and flattening-filter-free (FFF)), beam angle (0°–80°), skin-care cream type (water-based and silicon-based) and cream thickness (0–3 mm) using the EGSnrc Monte Carlo code. The densities of the water- and silicon-based cream were 0.92 and 1.14 g/cm<sup>3</sup>. The dose enhancement factor (DEF) defined as the ratio of the skin dose with skin-care cream to the skin dose without cream was calculated. It is found that the FF photon beam had higher DEF value than the FFF. For the water-based cream of 3 mm, the DEF for the FF beam was about 22.1% higher than that of the FFF. While for the silicon-based cream with the same thickness, the DEF was 24.2% higher. DEF value also increased with the beam angle. The DEF values were from 1.4 to 2.52 (water-based cream) and 1.42 to 2.68 (silicon-based cream) when the beam angle was increased from 20° to 80° using the 6 MV FF beams. Similarly, for the 6 MV FFF beams, the DEF values increased from 1.29 to 2.07 and 1.30 to 2.18 for the water- and silicon-based cream. These simulation results showed that the skin dose enhancement increased with an increase of beam angle, cream thickness, cream density, and the irradiation of FFF photon beams.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.683
Threshold uncertainty score0.564

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.277
Teacher spread0.264 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueAIMS bioengineeringSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207