MétaCan
Menu
Back to cohort
Record W3022494397 · doi:10.2196/16036

Comparison of the Effects of Automated and Manual Record Keeping on Anesthetists’ Monitoring Performance: Randomized Controlled Simulation Study

2020· article· en· W3022494397 on OpenAlex
Man-Kei Tse, Simon Y. W. Li, Tsz Hin Chiu, Chung Wai Lau, Carmen K. M. Lam, C. Cheng

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

venuePublished in a venue whose home country is Canada.
no affNo Canadian affiliation: this work is invisible to an affiliation-only frame.
No Canadian affiliation. An affiliation-only frame, the usual design, would never have seen this work. It is one of the works that make the case for inverting the frame.

Bibliographic record

VenueJMIR Human Factors · 2020
Typearticle
Languageen
FieldMedicine
TopicHealthcare Technology and Patient Monitoring
Canadian institutionsnot available
Fundersnot available
KeywordsWorkloadMedicineVigilance (psychology)Randomized controlled trialAnesthesiologyNurse anesthetistFidelityMedical emergencyAnesthesiaEmergency medicineComputer sciencePsychologySurgery

Abstract

fetched live from OpenAlex

BACKGROUND: Anesthesia information management systems (AIMSs) automatically import real-time vital signs from physiological monitors to anesthetic records, replacing part of anesthetists' traditional manual record keeping. However, only a handful of studies have examined the effects of AIMSs on anesthetists' monitoring performance. OBJECTIVE: This study aimed to compare the effects of AIMS use and manual record keeping on anesthetists' monitoring performance, using a full-scale high-fidelity simulation. METHODS: This simulation study was a randomized controlled trial with a parallel group design that compared the effects of two record-keeping methods (AIMS vs manual) on anesthetists' monitoring performance. Twenty anesthetists at a tertiary hospital in Hong Kong were randomly assigned to either the AIMS or manual condition, and they participated in a 45-minute scenario in a high-fidelity simulation environment. Participants took over a case involving general anesthesia for below-knee amputation surgery and performed record keeping. The three primary outcomes were participants' (1) vigilance detection accuracy (%), (2) situation awareness accuracy (%), and (3) subjective mental workload (0-100). RESULTS: With regard to the primary outcomes, there was no significant difference in participants' vigilance detection accuracy (AIMS, 56.7% vs manual, 56.7%; P=.50), and subjective mental workload was significantly lower in the AIMS condition than in the manual condition (AIMS, 34.2 vs manual, 46.7; P=.02). However, the result for situation awareness accuracy was inconclusive as the study did not have enough power to detect a difference between the two conditions. CONCLUSIONS: Our findings suggest that it is promising for AIMS use to become a mainstay of anesthesia record keeping. AIMSs are effective in reducing anesthetists' workload and improving the quality of their anesthetic record keeping, without compromising vigilance.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.112
Threshold uncertainty score0.385

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.051
GPT teacher head0.400
Teacher spread0.349 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it