MétaCan
Menu
Back to cohort
Record W3022697549 · doi:10.14740/cr1028

Diagnostic Accuracy of Cardiac Magnetic Resonance Versus Fractional Flow Reserve: A Systematic Review and Meta-Analysis

2020· review· en· W3022697549 on OpenAlexvenueno aff
Waqas Ullah, Sohaib Roomi, Hafez Mohammad Ammar Abdullah, Maryam Mukhtar, Zain Ali, Ping Ye, Donald Haas, Vincent M. Figueredo

Bibliographic record

VenueCardiology Research · 2020
Typereview
Languageen
FieldMedicine
TopicCardiac Imaging and Diagnostics
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineFractional flow reserveCutoffCoronary artery diseaseCardiologyInternal medicineCADDiagnostic accuracyMagnetic resonance imagingMeta-analysisCardiac magnetic resonanceRadiologyNuclear medicineCoronary angiographyMyocardial infarction

Abstract

fetched live from OpenAlex

BACKGROUND: Fractional flow reserve (FFR) is considered the gold standard for diagnosis of coronary artery disease (CAD). Stress Cardiac magnetic resonance (SCMR) has been recently gaining traction as a non-invasive alternative to FFR. METHODS: Studies comparing the diagnostic accuracy of SCMR versus FFR were identified and analyzed using Review Manager (RevMan) 5.3 and Stata software. RESULTS: A total of 28 studies, comprising 2,387 patients, were included. The pooled sensitivity and specificity for SCMR were 86% and 86% at the patient level, and 82% and 88% at the vessel level, respectively. When the patient-level data were stratified based on the FFR thresholds, higher sensitivity and specificity (both 90%) were noted with the higher cutoff (0.75) and lower cutoff (0.8), respectively. At the vessel level, sensitivity and specificity at the lower FFR threshold were significantly higher at 88% and 89%, compared to the corresponding values for higher cutoff at 0.75. Similarly, meta-regression analysis of SCMR at higher (3T) resolution showed a higher sensitivity of 87% at the patient level and higher specificity of 90% at the vessel level. The highest sensitivity and specificity of SCMR (92% and 94%, respectively) were noted in studies with CAD prevalence greater than 60%. CONCLUSIONS: SCMR has high diagnostic accuracy for CAD comparable to FFR at a spatial resolution of 3T and an FFR cut-off of 0.80. An increase in CAD prevalence further improved the specificity of SCMR.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.006
metaresearch head score (Gemma)0.107
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMetaresearch, Meta-epidemiology (narrow), Meta-epidemiology (broad), Research integrity
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Systematic review · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.797
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0060.107
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0230.007
Bibliometrics0.0010.003
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.001
Research integrity0.0010.003
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.227
GPT teacher head0.470
Teacher spread0.243 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designSystematic review
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations10
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueCardiology ResearchSame topicCardiac Imaging and DiagnosticsFrench-language works237,207