MétaCan
Menu
Back to cohort
Record W3023556837 · doi:10.1016/j.jhepr.2020.100119

Adding the oxygen carrier M101 to a cold-storage solution could be an alternative to HOPE for liver graft preservation

2020· article· en· W3023556837 on OpenAlexfundno aff
P Alix, David Val‐Laillet, Bruno Turlin, Ismaïl Ben Mosbah, Agnès Burel, Éric Bobillier, Claude Bendavid, Eric Delpy, Franck Zal, Anne Corlu, Karim Boudjéma

Bibliographic record

VenueJHEP Reports · 2020
Typearticle
Languageen
FieldMedicine
TopicOrgan Transplantation Techniques and Outcomes
Canadian institutionsnot available
FundersMinistère de la Santé et des Services sociaux
KeywordsMachine perfusionViaspanHepatocyteCold storageMedicineLiver transplantationChemistryTransplantationSurgeryBiologyBiochemistry

Abstract

fetched live from OpenAlex

Background & Aims Hypothermic oxygenated machine perfusion (HOPE) is a promising technique for providing oxygen to the liver during graft preservation; however, because of associated logistical constraints, addition of an oxygen transporter to static cold-storage solutions (SCS) might be easier. M101 is marine worm haemoglobin that has been shown to improve kidney preservation in the clinic when added to SCS. This study evaluated the effects of the addition of M101 to SCS on the quality of pig liver graft preservation. Methods Pig liver grafts were preserved using SCS, HOPE, or SCS+M101, and the liver functions were compared during cold preservation and after orthotopic allotransplantation (OLT) in pigs. Results During preservation of the liver grafts, mitochondrial function, ATP synthesis, antioxidant capacities, and hepatocyte architecture were better preserved, and free radical production, antioxidant activities, and inflammatory mediators were lower, with HOPE or SCS+M101 than with SCS alone. However, after 1 h of preservation, liver functions with HOPE were superior to those with SCS+M101. After 6 h of preservation and OLT, blood levels of aspartate and alanine aminotransferases and lactate dehydrogenase increased with a peak effect at Day 1 post-transplant; values were similar with HOPE and SCS+M101, and were significantly lower than those in the SCS group. At Days 1 and 3, tumor necrosis factor α levels remained lower with HOPE and SCS+M101 vs. SCS. At Day 7, liver cell necrosis and inflammation were less marked in both oxygenated groups. Conclusions When added to SCS, M101 effectively oxygenates liver grafts during preservation, preventing post-transplant injury; although graft performances are below those achieved with HOPE. Lay summary When transported between donors and recipients, even cold-stored liver grafts need oxygen to maintain their viability. To provide them with oxygen, we added a marine worm super haemoglobin (M101) to the cold-storage solution UWCS. Using a pig liver transplant model, we revealed that livers cold stored with UWCS+M101 showed improved oxygenation compared with simple cold-storage solutions, but did not reach the oxygenation level achieved with machine perfusion.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.059
GPT teacher head0.325
Teacher spread0.266 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations32
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueJHEP ReportsSame topicOrgan Transplantation Techniques and OutcomesFrench-language works237,207