MétaCan
Menu
Back to cohort
Record W3025427168 · doi:10.1088/1361-6439/ab9202

Inlaid microfluidic optics: absorbance cells in clear devices applied to nitrite and phosphate detection

2020· article· en· W3025427168 on OpenAlexafffund
Edward Luy, Sean Morgan, Joshua Creelman, Benjamin Murphy, Vincent J. Sieben

Bibliographic record

VenueJournal of Micromechanics and Microengineering · 2020
Typearticle
Languageen
FieldChemical Engineering
TopicAnalytical Chemistry and Sensors
Canadian institutionsDalhousie University
FundersCanada First Research Excellence FundNatural Sciences and Engineering Research Council of CanadaMarine Environmental Observation Prediction and Response Network
KeywordsAbsorbanceMicrochannelMicrofluidicsMaterials scienceOptical path lengthOpticsFabricationOptoelectronicsNanotechnology

Abstract

fetched live from OpenAlex

Abstract A novel type of microfluidic absorbance cell is presented here that inlays black poly(methyl methacrylate) (PMMA) into a clear PMMA substrate to realize an isolated optical channel with microlitre volumes. Optical measurements are frequently performed on microfluidic devices, offering effective, quick, and robust chemical analysis capabilities on small amounts of sample. Many lab-on-chip systems utilize micrometer-sized channels to analyze liquid samples via light-absorbance measurements, but this requires sophisticated coordination of light through a small cross-section, often requiring collimating and beam-steering optics. Here, we detail the fabrication process to realize long path length absorbance cells based on a simple hybrid-material approach. A z-shape microchannel structure crosses a clear-black interface at both ends of the absorbance cell, thereby creating integral optical windows that permit light coupling into a microchannel completely embedded in black PMMA. Furthermore, we have integrated v-groove prisms on either side of the microfluidic channel. The prisms enabled seamless integration with printed circuit boards and permit the optical elements to be located off-chip without use of epoxies or adhesives. Three path lengths, 10.4, 25.4, and 50.4 mm, were created and used to characterize the novel cell design using typical colorimetric measurements for nitrite and phosphate. We compare the attenuation coefficient measured by our optical cells with the literature, showing excellent agreement across nutrient concentrations from 50 nM–50 μM. The measurements were performed with well-known reagent-based methods, namely the Griess assay for nitrite and the molybdovanadophosphoric acid or the ‘yellow method’ for phosphate. The longest 50.4 mm path length cell had a limit-of-detection of 6 nM for nitrite and 40 nM for phosphate, using less than 12 μl of fluid. The inlaid fabrication method described permits robust and high-performance optical measurements with broad applicability for in situ marine sensors and for numerous lab-on-chip sensors based on colorimetric assays. One such application is shown whereby two inlaid absorbance cells are integrated with four microfluidic check valves to realize a complete lab-on-chip nitrite sensor.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.184
Teacher spread0.177 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations24
Published2020
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Micromechanics and MicroengineeringSame topicAnalytical Chemistry and SensorsFrench-language works237,207