MétaCan
Menu
Back to cohort
Record W3025586178 · doi:10.1080/15389588.2014.935358

Comparative Performance of Forward-Facing Child Restraint Systems on the C/FMVSS 213 Bench and Vehicle Seats

2014· article· en· W3025586178 on OpenAlexaff
Matthew R. Maltese, Suzanne Tylko, Aditya Belwadi, Caitlin M. Locey, Kristy B. Arbogast

Bibliographic record

VenueTraffic Injury Prevention · 2014
Typearticle
Languageen
FieldMedicine
TopicAutomotive and Human Injury Biomechanics
Canadian institutionsTransport Canada
Fundersnot available
KeywordsKinematicsSignificant differenceAccelerationTest benchCrash testAutomotive engineeringEngineeringMedicineCrashPhysicsComputer scienceMechanical engineering

Abstract

fetched live from OpenAlex

OBJECTIVE: The objective of this study was to evaluate the fidelity of the C/FMVSS 213 test bench, by comparing the dynamic performance of forward-facing child restraint systems (FFCRS) mounted on the C/FMVSS 213 sled bench versus mounted on a selection of production vehicle seats. METHODS: The C/FMVSS 213 bench or one of 3 second-row original equipment manufacturer vehicle seats was mounted to the deck of acceleration crash sled. An FFCRS with a restrained anthropomorphic test device (ATD) was secured by 3-point belt (3-PT) or LATCH lower anchor (LLA) on the C/FMVSS 213 bench or vehicle seat, with or without a tether. The sled was then exposed to a 48 km/h acceleration pulse. Three unique make and model vehicle seats and FFCRS were tested. Fifty-three sled tests were performed. RESULTS: When FFCRS were secured with LLA and no tether, little difference between the vehicle seats and 213 bench was observed. Similarly, when FFCRS were affixed with 3-PT and no tether, few kinematic variable differences achieved statistical significance; chest resultant acceleration was, on average, 9.1 g (SD=6.6, P=.006) higher on the vehicle seats compared to the bench, as was CRS seatback excursion (difference [Δ] of 39.8 mm, SD=32.7, P=.011) and ATD knee excursion (Δ=36.4 mm, SD=12.0, P<.001). However, when the tether was added to either the 3-PT or LLA attachment methods, the difference between the bench and vehicle seats was more pronounced. ATD kinematic measures such as head resultant acceleration (Δ=14.6 g, SD=7.2, P<.001) and pelvis resultant acceleration (Δ=8.6 g, SD=6.0, P=.005) were higher on the vehicle seats compared to the bench, as were the injury metrics for head and chest injury: ΔHIC15=162.2 (SD=87.4, P=.001) and ΔChest 3 ms clip=5.5 g (SD=6.2, P=.040). Of note, CRS (Δ=62.8 mm, SD=32.7, P=.000) and ATD head (Δ=66.3 mm, SD=30.9, P=.000) and knee (Δ=46.9 mm, SD=25.8, P=.001) forward excursion were all higher on the vehicle seats compared to the bench in 3-PT with tether condition. CONCLUSIONS: Without the tether attached, we observed few kinematic and kinetic differences between the vehicle seat and the C/FMVSS 213 bench, suggesting that the bench is an adequate surrogate for the vehicle seat in this condition. With the tether attached, we found significant differences between the C/FMVSS 213 bench and vehicle seats, suggesting that the fidelity of the bench could be improved in the tethered mode. When differences were statistically significant, excursion and injury metrics were generally greater on the vehicle seats than on the C/FMVSS 213 bench.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.612
Threshold uncertainty score0.416

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.025
GPT teacher head0.286
Teacher spread0.260 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2014
Admission routes1
Has abstractyes

Explore more

Same venueTraffic Injury PreventionSame topicAutomotive and Human Injury BiomechanicsFrench-language works237,207