MétaCan
Menu
Back to cohort
Record W3025754181 · doi:10.1002/mp.14237

Technical Note: Cardiac synchronized volumetric modulated arc therapy for stereotactic arrhythmia radioablation — Proof of principle

2020· article· en· W3025754181 on OpenAlexaff
Justin Poon, Kirpal Kohli, Marc W. Deyell, Devin Schellenberg, Stefan A. Reinsberg, Tony Teke, Steven Thomas

Bibliographic record

VenueMedical Physics · 2020
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsSurrey Memorial HospitalKelowna General HospitalUniversity of British Columbia
Fundersnot available
KeywordsTruebeamMedicineCardiac AblationRadiosurgeryCardiac cycleCardiac arrhythmiaBeam (structure)Linear particle acceleratorNuclear medicineAblationCardiologyInternal medicineRadiation therapyCatheter ablationAtrial fibrillationPhysicsOptics

Abstract

fetched live from OpenAlex

PURPOSE: Ventricular tachycardia (VT) is a rapid, abnormal heart rhythm that can lead to sudden cardiac death. Current treatment options include antiarrhythmic drug therapy and catheter ablation, both of which have only modest efficacy and have potential complications. Cardiac radiosurgery has the potential to be a noninvasive and efficient treatment option for VT. Cardiac motion, however, must be accounted for to ensure accurate dose delivery to the target region. Cardiac synchronized volumetric modulated arc therapy (CSVMAT) aims to minimize the dose delivered to normal tissues by synchronizing beam delivery with a cardiac signal, irradiating only during the quiescent intervals of the cardiac cycle (when heart motion is minimal) and adjusting the beam delivery speed in response to heart rate changes. METHODS: A CSVMAT plan was adapted from a conventional VMAT plan and delivered on a Varian TrueBeam linear accelerator. The original VMAT plan was divided into three interleaved CSVMAT phases, each consisting of alternating beam-on and beam-off segments synchronized to a sample heart rate. Trajectory log files were collected for the original VMAT and CSVMAT deliveries and the dose distributions were measured with Gafchromic EBT-XD film. RESULTS: Analysis of the trajectory log files showed successful synchronization with the sample cardiac signal. Film analysis comparing the original VMAT and CSVMAT dose distributions returned a gamma passing rate of 99.14% (2%/2 mm tolerance). CONCLUSIONS: The film results indicated excellent agreement between the dose distributions of the original and cardiac synchronized beam deliveries. This study demonstrates a proof of principle cardiac synchronization strategy for precise radiation treatment plan delivery and adjustment to a variable heart rate. The cardiac synchronized technique may be advantageous in radioablation for VT.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.954
Threshold uncertainty score0.810

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.296
Teacher spread0.281 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations22
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207