MétaCan
Menu
Back to cohort
Record W3026810513 · doi:10.1111/jvim.15794

Evaluation of the Freestyle Optium Neo H point-of-care device for measuring blood glucose concentrations in sick calves

2020· article· en· W3026810513 on OpenAlexaff
Tolga Karapınar, Kenan Çağrı Tümer, Sébastien Buczinski

Bibliographic record

VenueJournal of Veterinary Internal Medicine · 2020
Typearticle
Languageen
FieldVeterinary
TopicAnimal health and immunology
Canadian institutionsUniversité de MontréalCegep de Saint Hyacinthe
Fundersnot available
KeywordsAutoAnalyzerMedicineConfidence intervalVenous bloodAnimal scienceInternal medicine

Abstract

fetched live from OpenAlex

BACKGROUND: Data on the performance of a glucometer in calves with different diseases are currently lacking. OBJECTIVE: The primary objective of this study was to evaluate the reliability of a point of care glucometer in calves affected by different diseases relative to a traditional bench-top autoanalyzer. ANIMALS: One hundred ninety-six calves with different disorders in a referral hospital. METHODS: Prospective study. Venous blood samples were used for the determination of glucose concentrations in blood and plasma using the Freestyle Optium Neo H and autoanalyzer, respectively. Data were subjected to Passing-Bablok regression and Bland-Altman plots. The Freestyle Optium Neo H was the test method and the autoanalyzer was the reference method. The diagnostic performance of the glucometer relative to the autoanalyzer was assessed using 3 different plasma glucose concentrations. RESULTS: The Passing-Bablok regression for the glucometer against the reference method revealed the presence of both proportional bias (1.12; 95% confidence interval [CI], 1.07-1.18) and constant bias (-11.25; 95% CI, -16.0 to -7.70). The glucometer yielded 92.2%-100% sensitivity and 86.4%-96% specificity for the assessing glucose concentration based on different concentration thresholds. CONCLUSIONS AND CLINICAL IMPORTANCE: The Freestyle Optium Neo H showed proportional and constant biases relative to the reference method. The glucometer showed poor performance according to criteria recommended by the International Standards Organization and the American Society for Veterinary Clinical Pathology. However, the glucometer determined hypoglycemia with high sensitivity and specificity therefore it might be used to diagnose hypoglycemia in calves with different diseases until calf-specific POC glucometers are developed.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.007
metaresearch head score (Gemma)0.012
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.007
Threshold uncertainty score0.038

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0070.012
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.186
GPT teacher head0.404
Teacher spread0.217 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations10
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Veterinary Internal MedicineSame topicAnimal health and immunologyFrench-language works237,207