Extreme vibration increase of the heat transfer coefficient of short heat pipes
Bibliographic record
Abstract
Abstract The results of the heat transfer coefficient studies of the short linear heat pipes (HP’s) with a formed by the capillary-porous insert vapour channel in the Laval nozzle-liked form under high thermal loads and external vibrations are presented. Under high heat power loads the vaporization process in the capillary-porous evaporator and vapour propagation in the vapour channel acquires a pulsating character with a frequency of 400-500 Hz and the amplitude up to 103 Pa. For the first time it was experimentally detected that under external longitudinal vibration, attached to the HP’s body with an limited amplitude of 0.15 mm and frequency equal to the frequency of arising internal vapour pulsations, the HP’s heat transfer coefficient shows the resonance nature and increases by up to 20%. The increase in the heat transfer coefficient is due to the boiling process intensification in the grid HP’s capillary-porous evaporator.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.002 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".