MétaCan
Menu
Back to cohort
Record W3030116184 · doi:10.24908/iqurcp.10314

Validation of Breast Volume Measurement using Non-invasive Surface Scan

2018· article· en· W3030116184 on OpenAlexvenueaboutno aff
Rachel House

Bibliographic record

VenueInquiry Queen s Undergraduate Research Conference Proceedings · 2018
Typearticle
Languageen
FieldEngineering
TopicAnatomy and Medical Technology
Canadian institutionsnot available
Fundersnot available
KeywordsVolume (thermodynamics)Breast cancerMedicineStandard deviationBreast-conserving surgeryScannerBreast surgeryBreast tissueRadiologyNuclear medicineStandard of careRadiation therapyComputer scienceMedical physicsMastectomySurgeryMathematicsCancerArtificial intelligenceStatisticsInternal medicinePhysics

Abstract

fetched live from OpenAlex

ntroduction: Breast Cancer is the most frequently occurring cancer in Canadian women [1]. The standard of care normally involves breast conserving surgery and radiation therapy followed by breast reconstruction surgery. For successful breast reconstruction, the total volume loss must be accounted for. Unfortunately, the volume excised during surgery generally does not reflect total breast volume loss, for example, radiation therapy is known to cause volume loss of the breast [2]. Our goal is to provide the software and workflow necessary to calculate the breast volume using a non-invasive technique. By calculating and comparing the breast volume of the patient before undergoing reconstruction surgery to the baseline volume will help surgeon’s better estimate how much tissue needs to be replaced.
 Methods: A 3D surface scan of the patient’s chest is obtained. The scan is then imported into 3D Slicer where modules are used to isolate the target breast and calculate the volume .
 Results: The method provided to calculate breast volume is feasible using 3D Slicer and only requires one surface scan from the patient. The ground truth breast volume of the mannequin was 164mL with a standard deviation of 4.1ml (n=5). The volume of the mannequin’s breast was calculated using the workflow provided, the mean calculated volume was 160.8mL and the standard deviation was 4.7ml (n=4).
 Conclusion: Using a 3D surface scanner provides a non-invasive and quick way to calculate breast volume. This initial validation suggests this system may be accurate enough to aid the surgeon in the reconstruction process.
 References
 [1] Canadian Breast Cancer Society. (2015). Breast Cancer in Canada, 2015. Retrieved from https://www.cbcf.org/ontario/AboutBreastCancerMain/FactsStats/Pages/Breast-Cancer-Canada.asp
 [2] Haykal, Siba, Colin P. White, and Nicolas A. Guay. "An estimation of volume loss after radiation therapy on free flap breast reconstruction." Plastic and reconstructive surgery 131.6 (2013): 937e-939e.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.061
Threshold uncertainty score0.932

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.098
GPT teacher head0.337
Teacher spread0.239 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2018
Admission routes2
Has abstractyes

Explore more

Same venueInquiry Queen s Undergraduate Research Conference ProceedingsSame topicAnatomy and Medical TechnologyFrench-language works237,207