MétaCan
Menu
Back to cohort
Record W3030425877

Sample preparation of blood plasma enables baseline separation of iron metalloproteins by SEC-GFAAS

2020· article· en· W3030425877 on OpenAlexaff
Kerri Miller, Sophia Sarpong‐Kumankomah, Artem Egorov, Jürgen Gailer

Bibliographic record

VenueJournal of Chromatography A · 2020
Typearticle
Languageen
FieldMedicine
TopicIron Metabolism and Disorders
Canadian institutionsUniversity of Calgary
Fundersnot available
KeywordsChemistryChromatographyMass spectrometrySample preparationMetalloproteinInductively coupled plasma mass spectrometryInductively coupled plasmaTransferrinAnalytical Chemistry (journal)PlasmaMetalBiochemistry
DOInot available

Abstract

fetched live from OpenAlex

The analysis of human plasma for biomarkers holds promise to revolutionize disease diagnosis, but is hampered by the inherent complexity of the plasma proteome. One way to overcome this problem is to analyze plasma for a sub-proteome, such as the metalloproteome. Previous studies employing size-exclusion chromatography (SEC) coupled on-line to an inductively coupled plasma-atomic emission spectrometer (ICP-AES) have revealed that plasma contains ~12 copper, iron and zinc metalloproteins. This included the iron metalloproteins transferrin (Tf) and a recently identified haptoglobin-hemoglobin (Hp-Hb) complex, which is formed in plasma when red blood cells rupture. Since this SEC-ICP-AES method required a sample volume of 500 µL to generate diagnostically useful results, we sought to develop an alternative SEC-based hyphenated approach using a smaller SEC column (150 × 5 mm I.D.) and a graphite furnace atomic absorption spectrometer (GFAAS) as the iron-specific detector. A designed interface enabled the integration of the SEC system with the GFAAS. Baseline separation between the Hp-Hb complex and Tf was achieved by developing a sample preparation procedure which involved the chelating agent-based mobilization of Fe from Tf to a small molecular weight Fe complex. Spiking of human plasma (1.0 mL) with red blood cell lysate (1–2 µL) increased only the intensity of the Fe peak corresponding to the Hp-Hb complex, but not that of Tf. Since the developed SEC-GFAAS method requires only 50 µL of plasma for analysis, it can now be employed for the cost-effective quantification of the clinically relevant Hb-Hp complex in human plasma in <50 min.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.010

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0010.002
Insufficient payload (model declined to judge)0.0020.003

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.272
Teacher spread0.260 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Chromatography ASame topicIron Metabolism and DisordersFrench-language works237,207