MétaCan
Menu
Back to cohort
Record W3031687845 · doi:10.1088/1361-6498/ab96d6

A comparison of consumer-grade electronic radon monitors

2020· article· en· W3031687845 on OpenAlexafffundabout
Pam Warkentin, Erin Curry, Oghenekome Michael, Brian Bjorndal

Bibliographic record

VenueJournal of Radiological Protection · 2020
Typearticle
Languageen
FieldHealth Professions
TopicRadioactivity and Radon Measurements
Canadian institutionsPublic Safety Canada
FundersHealth Canada
KeywordsRadonEnvironmental scienceRadon exposureEnvironmental healthMedicine

Abstract

fetched live from OpenAlex

Abstract Radon is a radioactive gas which is naturally occurring in soil and can accumulate to concentrated levels inside homes and buildings. Exposure to elevated levels of radon leads to an increased risk of developing lung cancer. In recent years there has been a rise in the popularity of consumer-grade electronic radon monitors. The monitors are appealing to homeowners due to the ease of use and the ability to keep track of radon levels during the process of conducting a radon test. However, there is currently no independent process to evaluate the relative performance of these monitors against known levels of radon. In this study, three sample units of six different models representing three different manufacturers of consumer-grade electronic radon monitors were exposed to three different levels of radon in a controlled environment to evaluate their precision and accuracy. Two separate tests were conducted at the Canadian guideline level to accommodate for ‘indoor winter’ and ‘summer’ conditions. The purpose of the study was to compare the performance of the different consumer-grade electronic radon monitors and determine which factors should be considered when using these monitors to inform mitigation decisions. The monitors had a range of uncertainty from 2%–15% with a range of precision from 1%–24%. The monitors performed better at higher radon levels than at levels near the Canadian guideline level of 200 Bq m −3 , and slightly better during ‘summer’ conditions than during ‘indoor winter’ conditions. While the monitors provide homeowners with a very specific number indicating their radon level, it was noted that this number should be considered with respect to a ‘confidence ratio’ or ‘range’ which could be done through a publicly available online tool which could provide the radon level range for a given radon level and device grade.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.498
Threshold uncertainty score0.874

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.002
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.286
GPT teacher head0.462
Teacher spread0.177 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations26
Published2020
Admission routes3
Has abstractyes

Explore more

Same venueJournal of Radiological ProtectionSame topicRadioactivity and Radon MeasurementsFrench-language works237,207