MétaCan
Menu
Back to cohort
Record W3033366455 · doi:10.1111/clr.13623

Maxillary implant overdenture retained by four unsplinted attachments and opposed by a natural or fixed dentition: One‐year clinical outcomes

2020· article· en· W3033366455 on OpenAlexaboutno aff
Alice Bouhy, Eric Rompen, Marc Lamy, Caroline Legros, Geoffrey Lecloux, France Lambert

Bibliographic record

VenueClinical Oral Implants Research · 2020
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
FundersInternational Trachoma Initiative
KeywordsDentitionDentistryOrthodonticsMedicineImplantSurgery

Abstract

fetched live from OpenAlex

OBJECTIVES: The aim of this prospective study was to evaluate the implant, prosthesis, and patient-reported outcomes of maxillary removable prostheses retained by 4 implant-supported study abutments after a follow-up period of 1 year in patients with natural teeth or a fixed rehabilitation in the mandible. MATERIALS AND METHODS: A total of 30 patients were included, and all received 4 implants in the upper maxilla. After 12 weeks, the prostheses were connected to the implant with unsplinted attachments. The implant and prosthodontics outcomes were assessed over a follow-up period of 1 year. Patient-reported outcome measures (PROMs) were evaluated with the Oral Health Impact Profile (OHIP-20) questionnaire and an adaptation of the McGill Denture Satisfaction Instrument using a visual analogue scale (VAS). RESULTS: A single patient dropped out. At the post-operative 12-week follow-up, 79.3% (95% CI: 64.6%-94.1%) of the patients displayed peri-implant mucosa hyperplasia and 69.0% (95% CI: 52.1%-85.8%) showed pain. After 1 year, 16 implants failed in 10 patients, leading to an implant survival rate of 86.2% (95% CI: 79.0%-92.5%), and the mean peri-implant bone loss was 1.01 ± 0.77 mm (95% CI: 0.85-1.16 mm). The prosthesis survival rate was 96.6% (95% CI: 82.2%-99.9%). The OHIP-20 and VAS scores both improved significantly from baseline to 1 year (p < .001). CONCLUSION: The implant survival rate was lower compared to the literature for the upper maxilla. Despite the encountered problems, PROMs showed significant improvement with the implant overdenture retained by 4 unsplinted implants compared to conventional dentures.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.003
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow), Research integrity, Insufficient payload (model declined to judge)
Consensus categoriesInsufficient payload (model declined to judge)
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.472
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0030.003
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0020.001
Bibliometrics0.0000.001
Science and technology studies0.0000.001
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0010.003
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.326
GPT teacher head0.521
Teacher spread0.195 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; both teacher heads agree on what is shown here.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations21
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueClinical Oral Implants ResearchSame topicDental Implant Techniques and OutcomesFrench-language works237,207