MétaCan
Menu
Back to cohort
Record W3033536690 · doi:10.2106/jbjs.oa.19.00066

Wear Rates of XLPE Nearly 50% Lower Than Previously Thought After Adjusting for Initial Creep

2020· article· en· W3033536690 on OpenAlexaff
Amir Khoshbin, James S. Wu, Sarah Ward, Luana Torres Monteiro Melo, Emil H. Schemitsch, James P. Waddell, Amit Atrey

Bibliographic record

VenueJBJS Open Access · 2020
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsWestern UniversitySt. Michael's Hospital
Fundersnot available
KeywordsPolyethyleneCreepCross-linked polyethyleneMedicineTotal hip arthroplastyRadiographyFemoral headSurgeryMaterials scienceComposite material

Abstract

fetched live from OpenAlex

BACKGROUND: The ideal bearing combination for total hip arthroplasty (THA) remains debatable. Highly cross-linked polyethylene (XLPE) is widely used, but long-term wear rates are not fully known, nor is how much the initial "creep," if any, affects overall wear. Additionally, the use of oxidized zirconium (OxZir) is purported to lower polyethylene wear rates, but this has not been proven. We present the 10-year data of a cohort of patients who underwent THA. Patients were prospectively randomized to 1 of 4 bearing combinations: a conventional ultra-high molecular weight polyethylene (UHMWPE) or XLPE acetabular liner coupled with either a cobalt-chromium (CoCr) or OxZir femoral head. The aims of the study were to (1) assess the extent to which creep affected overall wear rates and (2) assess wear rates between OxZir and CoCr with polyethylene. METHODS: A total of 92 hips (92 patients) between the ages of 22 and 65 years (mean, 52.2 ± 9.3 years) were randomized to 4 groups. At 10 years, 70 (76%) of the hips were available for analysis; patients who had undergone revision, had died, or were lost to follow-up were excluded from final analysis. Radiographic analysis was performed using a validated digital assessment program to determine linear, volumetric, and directional wear of the polyethylene for all 4 bearing couples. Radiographic assessments were performed immediately postoperatively, at 6 and 12 weeks, and then annually for a minimum of 10 years. RESULTS: XLPE had significantly lower wear rates than UHMWPE. Once creep was eliminated, annual and overall wear rates were nearly 50% lower than have been previously reported. This was proportionally more important in the XLPE group than in the UHMWPE group. There was a nonsignificant trend toward a lower wear rate with OxZir heads. CONCLUSIONS: Creep plays a notably more important role than first thought. Once creep was eliminated, the overall wear rate was even lower than previously assumed. This has important implications for the overall survivorship of hip arthroplasty implants. LEVEL OF EVIDENCE: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.010

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.100
GPT teacher head0.420
Teacher spread0.320 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations24
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueJBJS Open AccessSame topicOrthopaedic implants and arthroplastyFrench-language works237,207