Abstract

fetched live from OpenAlex

Bone is a dynamic and mechanically active tissue that changes in structure over the human lifespan. The products of the bone remodeling process have been studied substantially using traditional two-dimensional techniques. Recent advancements in X-ray imaging technology via desktop micro-computed tomography (µCT) and synchrotron radiation micro-computed tomography (SRµCT) have allowed for the acquisition of high-resolution three-dimensional (3D) scans of a larger field of view (FOV) than other 3D imaging techniques (e.g., SEM) providing a more complete picture of microscopic structures within human cortical bone. The specimen should be accurately centered within the FOV, however, to limit the appearance of streak artifacts known to impact data analysis. Previous studies have reported procurement of irregularly shaped rectilinear bone blocks that result in imaging artifacts due to uneven edges or image truncation. We have applied a geological sampling protocol (coring) to procure consistently sized cortical bone core specimens for SRµCT experiments from the anterior aspect of human femora. This coring method is efficient and minimally destructive to tissue. It creates uniform cylindrical samples that decrease imaging artifacts by nature of being isometric during rotation and providing a uniform path length for X-ray beams throughout scanning. Image processing of X-ray tomographic data of cored and irregularly shaped samples confirms the potential of the technique to improve visualization and analysis of cortical bone microarchitecture. A goal of this protocol is to deliver a reliable and repeatable method for the extraction of cortical bone cores that is adaptable for various types of high-resolution bone imaging experiments. An overarching goal of the work is to create a standardized cortical bone procurement for SRµCT that is affordable, consistent, and straightforward. This procedure may further be adapted by researchers in related fields who commonly evaluate hard composite materials such as in biological anthropology, geosciences, or material sciences.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.200
Threshold uncertainty score0.444

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.053
GPT teacher head0.463
Teacher spread0.410 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Visualized ExperimentsSame topicMedical Imaging Techniques and ApplicationsFrench-language works237,207