MétaCan
Menu
Back to cohort
Record W3034960555

Simulated performance of HC-290 in air conditioners.

2011· article· en· W3034960555 on OpenAlexaboutno aff
Atul S. Padalkar, Kundlik V. Mali, S. Devotta

Bibliographic record

VenueProceedings of the 23<sup>rd</sup> IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development. · 2011
Typearticle
Languageen
FieldDecision Sciences
TopicRisk and Safety Analysis
Canadian institutionsnot available
Fundersnot available
KeywordsRefrigerantAir conditioningFlammabilityEnvironmental scienceCondenser (optics)ConditionersCoefficient of performanceThermodynamicsEngineeringEnvironmental engineeringMechanical engineeringPhysics
DOInot available

Abstract

fetched live from OpenAlex

As per the accelerated phase out schedule of Montreal Protocol, HCFC-22 has to be phase out by 2020 in Article 5 countries and 2030 in non Article 5 countries. Being natural substance, HC-290 is considered as alternative to HCFC-22. In the case of HC-290, the consideration must be given to flammability. After achieving the reduction in charge of HC-290 up to 30% lower that of HCFC-22, this paper focuses on simulation studies for further reduction of HC-290 charge for air conditioners both window and split air conditioner using IMST ART v3.3. A 5.16 kW capacity window air conditioner and 4.95 kW capacity split air conditioners designed for HCFC-22 are considered. The air conditions considered are as per the Indian Standard IS 1391 (1992) Part I. First the baseline performance is established with HCFC-22 for both the air conditioners. The performance of HC-290 is predicted under drop-in condition. Under drop-in test, (replacing HCFC-22 with HC-290 without any other system changes) for both air conditioners, the cooling capacity is lower and COP is higher than that of HCFC-22. The optimized charge of HC-290 is in the range 48 to 50% that of HCFC-22 by weight. Standards like EN 378 specify the allowable charge of HC-290 in a closed space to avoid risk due to flammability. The condenser is the major component of air conditioner which contains the large amount of refrigerant. Therefore, the various combinations of low size condenser tube OD, ranging from 9.52 to 3.18 mm is considered to reduce charge with performance equivalent to HCFC-22. The lowest HC-290 charge is with 4.75 mm tube OD condenser for both window air conditioner as well as split air conditioner. For window air conditioner with 4.75 mm OD tube, the cooling capacity is 9.2% lower than that of HCFC-22 and COP is 2.9% higher than that of HCFC-22. For split air conditioner with 4.75 mm OD tube, the cooling capacity is 5.8% lower than that of HCFC-22 and COP is 7.1% higher than that of HCFC-22.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.007
metaresearch head score (Gemma)0.005
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.268
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0070.005
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.002
Science and technology studies0.0010.001
Scholarly communication0.0010.006
Open science0.0030.001
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.036
GPT teacher head0.297
Teacher spread0.261 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2011
Admission routes1
Has abstractyes

Explore more

Same venueProceedings of the 23<sup>rd</sup> IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.Same topicRisk and Safety AnalysisFrench-language works237,207